Altinex MAX Series manual DOxxyyzzkk, DoxxyyzzkkUn, SWUx

Page 18

MATRIX SWITCHERS

This command is used to select multiple inputs and multiple outputs without switching and then switch them together with a single command. This is a very useful command for scene or salvo switching or for controlling through a PC.

If n = 1, units will respond to any command. If n= 0, then none of the units will respond to any issued command, except [UIDn].

A typical sequence would look like this: [I01O02U2P][I04O01U2P][I08O03U3P][I05O04 U4P]. Set the path for three different switchers with these commands and then switch them all together with the [SW] command.

[DOxxyyzzkk]

xx- Input connected to output 1

yy- Input connected to output 2

zz- Input connected to output 3

kk- Input connected to output 4

Connect any 4 inputs to any 4 outputs of the MAX Switcher with a single command. This command allows a quick way of connecting inputs and outputs without sending 4 commands with a 50 ms delay between each command. For example, if input 3 needs to be connected to outputs 1,2,3,4, then the following command can be used [DO03030303]. If input 4,5,6,7 need to be connected to outputs 1,2,3,4, then the following command is issued [DO04050607]. The switching of all inputs occurs simultaneously for all outputs. If sync delay is in effect, then it will be used before switching. Input 00 is used to turn a channel 'OFF'. For example, if you want to disconnect all channels use following command [DO00000000]

[DoxxyyzzkkUn]

xx- Input connected to output 1

yy- Input connected to output 2

zz- Input connected to output 3

kk- Input connected to output 4

n- unit ID number 0-9, A-Z, a-z

Connect any 4 inputs to any 4 outputs on a MAX Switcher with a specific unit ID number. This command allows quick connection of

inputs and outputs of the specific MAX Switcher without sending four different commands with 50 ms delays between each command. For example, if input 3 needs to be connected to outputs 1,2,3,4 of the unit with ID=4, then the following command can be used [DO03030303U4]. If inputs 4,5,6,7 need to be connected to outputs 1,2,3,4 on the MAX switcher with unit ID number 8, then the

following command is issued [DO04050607U8].

The switching of all inputs occurs simultaneously for all outputs. If sync delay is in effect, then it will be used before switching. The unit ID needs to be set for the switcher that needs to be controlled before using this command. Input 00 is used to disconnect output 1 through 4. For example, if you want to disconnect all outputs on the MAX Switcher with unit ID number 2, then use the following command [DO00000000U2].

[SW]

Immediately switch the inputs to outputs, which are previously set through path commands.

First set the path using [InnOmmP] or [InnOmmUxP]. Then issue a single [SW] command to switch all connections simultaneously, which are loaded by path commands. If Sync delay is enabled the [SW] command will delay switching for that period. This command is available only when switchers to be controlled are enabled using [UID1]. This command is a very useful for scene or salvo switching or for controlling through a PC.

[SWUx]

x - Unit ID number 0-9, A-Z, and a-z

This command immediately switches inputs to outputs on a specific switcher with a specified unit ID number, which is previously set through a path command.

First the path is set through a [InnOmmUxP] command and then a single [SWUx] command is issued to switch all connections simultaneously. If Sync delay is enabled, the

17

Image 18
Contents MAX Series Table of Contents IntroductionPRECAUTIONS/SAFETY Warnings About Your MAX Series Matrix Switcher Technical SpecificationDiagram of FRONT/BACK Panel Audio Ports L&R Back Panel ControlH & V SYNC, Composite Sync RS-232 Ports 1&2Application Diagram Matrix Switchers Matrix Switchers CONGRATULATIONS! YOU are Done Installing Your SwitcherOperation Front Panel ControlSET Unit Sync Delay Function Saving Switcher Configuration in MemoryBaud Rate Setting Connect Input to OutputSET Unit ID Number Select SignalIR Control Recall PRE-SET MemoryLock / Unlock Front Panel ResetProgramming Commands RS-232 Programming and ControlInnOmmA CODEnInnOmmS IkkOnnLSDELnn Unit BControl Commands RsetInnOmmP SELnUxInnOmm InnOmmUxDOxxyyzzkk DoxxyyzzkkUnSWUx RCLn FDBKnSAVn Projector ControlMAX Switcher IR-CONTROL ModeWired Infra-red Receiver Please noteCables and Accessories Troubleshooting Guide Return Policy Limited WarrantyAltinex Policy Contact Information