Altinex MAX Series manual Cables and Accessories

Page 21
Model No.
DA1296RM
TM1277
RC5251IR
CB4100MR
CB4300MR
CB4200MR
CB4400MR
CB5000PL

MATRIX SWITCHERS

CABLES AND ACCESSORIES

8

Description

RACK MOUNTING BRACKETS

19”-3U Rack Mount Ears

TABLE MOUNT BRACKETS

3U High, 1 Rack - Wide

CONTROL OPTIONS

Infra-Red Hand-held Remote Control Transmitter and Receiver with 6 ft cable

4 BNC TO 4 BNC COAXIAL CABLE

Bulk high resolution 4 coax cable (500 ft minimum)

Bulk super high resolution 4 coax cable (500 ft minimum)

5 BNC TO 5 BNC COAXIAL CABLE

Bulk high resolution 5 coax cable (500 ft minimum)

Bulk super high resolution 5 coax cable (500 ft minimum)

Bulk high resolution 5 coax cable (500ft minimum) PLENUM-FLEX

All cables listed above are a pre-cut series available in lengths of 6 ft, 12 ft, 25 ft, 50 ft, 75 ft, 100 ft and 150 ft with molded BNC connectors. Please call 1- 714-990-2300 for more information.

FAQ (Frequently Asked Questions)

9

4

5

controlled from the front panel.

Does the MAX Series come with rack mounts?

How does one increase the number of inputs or outputs on the switcher?

to activate Control through the front panel. If still it doesn’t work then reset the switcher to factory defaults by pressing and holding the “VIDEO” button.

Yes, two rack mount ears should be included with the unit. If you did not receive them, please call us and they will be sent to you.

To increase the number of inputs, one can add a second switcher and loop outputs of the first switcher to the inputs of the second switcher. For example, to create a 12x4 MAX Switcher, route 4 outputs of first 8x4 switcher to the input of a second 8x4 switcher. So 8 inputs go into switcher 1 and inputs 9- 12 go into switcher 2, while outputs 1-4 are taken from the second switcher. To increase the number of outputs, use a second switcher and an interface with dual outputs. For example, to create an 8x8

No

Question

 

 

1How do I know which input is connected to which output?

2The MAX Switcher does not communicate with a PC or Control System.

3The MAX Switcher can not be

Answer

If you press a desired input button, the fast flashing LED on OUTPUT will indicate the present connections of this input to all connected outputs.

When you experience lack of communication, please check the following:

1.The baud rate setting.

2.Cable connection.

3.Unit ID setting.

Make sure that the front panel is not disabled. Press and hold the STATUS key

6

7

May I switch audio separate from the video?

May I control multiple switchers with one RS-232 card?

MAX Switcher, use two 8x4 MAX Switchers where inputs to both switchers come from an output distribution amplifier.

Yes, the MAX Series has full breakaway capability of Red, Green, Blue, Sync, and Audio through RS-232 control.

Yes, the MAX Series is designed to allow the assignment of different ID numbers to individual units. This feature makes it possible to control multiple switchers through the same

20

Image 21
Contents MAX Series Introduction Table of ContentsPRECAUTIONS/SAFETY Warnings Technical Specification About Your MAX Series Matrix SwitcherDiagram of FRONT/BACK Panel H & V SYNC, Composite Sync Back Panel ControlAudio Ports L&R RS-232 Ports 1&2Application Diagram Matrix Switchers Matrix Switchers Operation Installing Your SwitcherCONGRATULATIONS! YOU are Done Front Panel ControlBaud Rate Setting Saving Switcher Configuration in MemorySET Unit Sync Delay Function Connect Input to OutputIR Control Select SignalSET Unit ID Number Recall PRE-SET MemoryProgramming Commands ResetLock / Unlock Front Panel RS-232 Programming and ControlInnOmmS CODEnInnOmmA IkkOnnLUnit B SDELnnRset Control CommandsInnOmm SELnUxInnOmmP InnOmmUxDOxxyyzzkk DoxxyyzzkkUnSWUx SAVn FDBKnRCLn Projector ControlWired Infra-red Receiver IR-CONTROL ModeMAX Switcher Please noteCables and Accessories Troubleshooting Guide Altinex Policy Limited WarrantyReturn Policy Contact Information