MULTITASKER™

If ‘F’ is included, use the [OFFmCnPF] command or the [OFFmCnFP] command.

FEEDBACK OPERATION

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if ‘F’ is included at the end of a command string.

Command Format: [OFF…..F]

Example:

[OFF1C2F]: if path is not set

[OFF1C2PF]: if path is set

10.[…S] – SAVE

This command will save the configuration

command being sent in memory. When sending the command [I1O1C4S], after reset or power up, Input 1 will be connected to Output 1 on C4. This command only saves the Input 1 to Output 1 connection above. In order to save all the current settings, use the [CnS] command.

11.[…F] – FEEDBACK

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if ‘F’ is included at the end of a command string.

12.[…P] – PATH

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in ‘P’ are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples for the [ON] and [OFF] commands.

Example:

There is an MT110-102in slot 4. Input 1 is connected to all outputs and all outputs are on. The PATH command has been used to set Input 2 to Output 1 and turn off Outputs 2 and 3 simultaneously. If checking the status prior to sending the [SW] command, the feedback will appear as follows for the above connection settings:

In01-Out01 ON 32/32 P=02 In01-Out02 ON 32/32 P=OFF

In01-Out03 ON 32/32 P=OFF etc…

The notation "P=" at the end of the line indicates the path condition is active. "P=02" on the Output 1 line indicates that after the [SW] command, Input 2 will be connected to Output 1.

The notation "P=OFF" on lines 2 and 3 indicates that Outputs 2 and 3 will be turned off after the [SW] command is executed.

13.[SW] – SWITCH

This command immediately connects inputs and outputs previously set with the PATH command. The command switches all paths set on this card and all other cards in the enclosure.

Example:

[ON1C4P]

[OFF3C8P]

[SW]

14.[IO]

This command connects a single input to a single output in the current matrix configuration.

Command Format: [ImOxCnUi]

m= Input (m= # from 1 to 8) x = Output (x = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Connect Input 1 to Output 1 for the MT110-102in slot 5. Send the command [I1O1C5] and Input 1 will be connected to Output 1.

15.[IO*]

This command connects a single input to all the outputs in the current matrix configuration.

400-0132-005

14

Image 15
Contents MT110-100/102 Table of Contents General Precautions / Safety WarningsInstallation CleaningMT110-100/102 Technical SpecificationsDescription of MT110-100/102 Diagram 1 Typical Setup Application DiagramMultitasker Diagram 2 Internal View MT110-100 SwitcherMatrix Diagram 3 Internal View MT110-102 RS-232 Control Installing Your MT110-100/102Description of Commands OperationCnS ConfigurationConnection Output Volume VER Saved Group Operation STA1STA0 MT110-102 cardSingle Card Operation Path OperationFeedback Operation OFF12. …P Path SW Switch10. …S Save 11. …F FeedbackFBD CLROSI OSOSID+ RSISIDn SIDnCiRMG RSN25. WR RMCTest Remove ALL GroupsG1-G8EMPTY 28. RDVolume Ramping Feature MT110-102 only RDN MT110-102 only Ramp Time = 16 Seconds Ramptime = 6 SecondsMATmXy 16 xHelp OSO OFFCLR OSINo Sound Troubleshooting GuideLED is not LIT LED is Blinking REDSound Level is LOW Limited WARRANTY/RETURN PolicyAltinex Policy Distorted Sound