Altinex MT110-100/102 manual RDN MT110-102 only

Page 21

MULTITASKER™

35.[RDN] MT110-102 ONLY

This command ramps the output volume down to a level of 00 at a rate defined using the [RAMP] command.

Command Format: [RDNCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on Output 1 from a starting level of 32 down to 00 for the card in slot 8. Send the commands [SEL1C8] then [RDNC8] and the system will respond with the following feedback:

[31][30][29]…[00]

36.[RUPm] MT110-102 ONLY

This command ramps UP the output volume for the specified output on the card. The ramping will continue to its maximum level at the rate defined using the [RAMP] command. The ramping may be stopped at any time using the [RST] command.

Command Format: [RUPmCnUi]

Cn = Card ID (n = # from 1 to max slots)

m = Output No. (n = # from 1 to 8)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for Output 2 from a starting level of 10 to the maximum level of 32 for the card in slot 8. Send the command [RUP2C8] and the system will respond with the following feedback:

[11][12][13][14]…[32]

37.[RUPm=xx] MT110-102 ONLY

This command ramps a specified output’s volume to a user defined level at a rate defined using the [RAMP] command.

Command Format: [RUPm=xxCnUi]

m= Output No. (m = # from 1-8) xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on output 7 from a starting level of 1 to a level of 20 for the card in slot 8. Send the command [RUP7=20C8] and the system will respond with the following feedback:

[02][03][04]…[20]

38.[RDNm] MT110-102 ONLY

This command ramps DOWN the output volume for the specified output on the card. The ramping will continue to its minimum level at the rate defined using the [RAMP] command. The ramping may be stopped at any time using the [RST] command.

Command Format: [RDNmCnUi]

Cn = Card ID (n = # from 1 to max slots)

m = Output No. (n = # from 1 to 8)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for output number 8 from a starting level of 32 down to 00 for the card in slot 8. Send the command [RDN8C8] and the system will respond with the following feedback:

[31][30][29]…[00]

400-0132-005

20

Image 21
Contents MT110-100/102 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralMT110-100/102 Technical SpecificationsDescription of MT110-100/102 Diagram 1 Typical Setup Application DiagramMultitasker Diagram 2 Internal View MT110-100 SwitcherMatrix Diagram 3 Internal View MT110-102 Description of Commands Installing Your MT110-100/102Operation RS-232 ControlConnection Output Volume ConfigurationVER CnSSaved STA0 STA1MT110-102 card Group OperationFeedback Operation Path OperationOFF Single Card Operation10. …S Save SW Switch11. …F Feedback 12. …P PathOSI CLROSO FBDSIDn RSISIDnCi SID+ 25. WR RSN RMC RMGG1-G8EMPTY Remove ALL Groups28. RD TestVolume Ramping Feature MT110-102 only RDN MT110-102 only Ramp Time = 16 Seconds Ramptime = 6 SecondsMATmXy 16 xHelp CLR OFFOSI OSOLED is not LIT Troubleshooting GuideLED is Blinking RED No SoundAltinex Policy Limited WARRANTY/RETURN PolicyDistorted Sound Sound Level is LOW