MULTITASKER™

43.[MUT0] MT110-102 ONLY

This command turns on the all the outputs without changing the input port selected and without changing any volume settings.

Command Format: [MUT0CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [MUT0C4] to enable the outputs for the card in slot 4.

44.[MUT1] MT110-102 ONLY

This command turns off all the outputs without changing the input port selected and without changing any output volume settings.

Command Format: [MUT1CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [MUT1C4] to mute all the outputs for the card in slot 4.

45.[MATmXy]

The matrix command allows the matrix switcher to be setup for different matrix sizes. The following tables show how the inputs and outputs will be configured when the matrix is changed. The input and output layouts are as viewed from the front of the card.

Example:

In the 8x4 configuration, when Input 1 is connected to Output 4, the entire channel, 1a and 1b, will be switched to outputs 4a and 4b respectively.

Command Format: [MATmXyCnUi]

m = number of inputs (m = 16, 8 or 4)

y = number of outputs (y = 8, 4 or 2)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

16 x 8

 

INPUTS

OUTPUTS

9

 

1

1

10

 

2

2

11

 

3

3

12

 

4

4

13

 

5

5

14

 

6

6

15

 

7

7

16

 

8

8

 

 

 

 

 

 

8 x 4

 

 

INPUTS

OUTPUTS

5 a

 

1 a

1 a

5 b

 

1 b

1 b

6 a

 

2 a

2 a

6 b

 

2 b

2 b

7 a

 

3 a

3 a

7 b

 

3 b

3 b

8 a

 

4 a

4 a

8 b

 

4 b

4 b

 

 

 

 

 

 

4 x 2

 

 

INPUTS

OUTPUTS

3 a

 

1 a

1 a

3 b

 

1 b

1 b

3 c

 

1 c

1 c

3 d

 

1 d

1 d

4 a

 

2 a

2 a

4 b

 

2 b

2 b

4 c

 

2 c

2 c

4 d

 

2 d

2 d

46.[HELP]

This command displays information available for the MultiTasker™ interface commands.

Command Format: [HELPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

400-0132-005

22

Image 23
Contents MT110-100/102 Table of Contents General Precautions / Safety WarningsInstallation CleaningMT110-100/102 Technical SpecificationsDescription of MT110-100/102 Diagram 1 Typical Setup Application DiagramMultitasker Matrix Diagram 2 Internal View MT110-100Switcher Diagram 3 Internal View MT110-102 RS-232 Control Installing Your MT110-100/102Description of Commands OperationCnS ConfigurationConnection Output Volume VERSaved Group Operation STA1STA0 MT110-102 cardSingle Card Operation Path OperationFeedback Operation OFF12. …P Path SW Switch10. …S Save 11. …F FeedbackFBD CLROSI OSOSID+ RSISIDn SIDnCiRMG RSN25. WR RMCTest Remove ALL GroupsG1-G8EMPTY 28. RD Volume Ramping Feature MT110-102 only RDN MT110-102 only Ramp Time = 16 Seconds Ramptime = 6 SecondsHelp MATmXy16 x OSO OFFCLR OSINo Sound Troubleshooting GuideLED is not LIT LED is Blinking REDSound Level is LOW Limited WARRANTY/RETURN PolicyAltinex Policy Distorted Sound