Altinex MT104-108 …S Save, …F Feedback, …P Path, SW Switch, Command Format HELPCnUi, Help, 11. WR

Page 10

MULTI-TASKER™

6.[…S] – Save

This command will save the configuration command being sent in memory. When sending the command [ON1C4S], after reset or power up, output 1 on C4 will be enabled.

7.[…F] – Feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

8.[…P] – Path

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. See examples in ON and OFF commands.

9.[SW] – Switch

The switch command immediately connects inputs and outputs, which were previously set with the path command. This command effects this card and all other cards in the MT100-100.

Example:

[ON1C6U3P]

[ON3C7U3P]

[SW]

The system will return feedback as OK if the unit ID is zero.

Command Format: [HELPCnUi]

Cn = card ID number (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9) ( refer to the MT100-100 user’s guide for explanation)

10.[HELP]

This command displays information available for the Multi-Tasker interface commands.

Example:

In order to view the RS-232 commands available for the MT104-108card in slot 2 of unit 3, send the command [HELPC2U3]. The

commands along with a brief description will be displayed in the Terminal Window

11. [WR]

This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups.

Command Format: [WRCn…GkUi]

Cn

= card ID (n = slot # from 1 to max slots)

Gk

= group number (k = # from 1-9)

Ui

= unit number (i = # from 0-9)

Example:

To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2 and 3 will be grouped together as group 5 of unit 1.

12. [CLR]

This command clears the members for a single group or for all nine groups.

Command Format: [CLRGkUi]

Gk

= group number (k = # from 1-9)

Ui

= unit number (i = # from 0-9)

Example:

1)To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only.

2)To clear all groups of unit 1, send the [CLRG[U1] command.

13.[G]

This command is used to request group data. With the command, the user can identify which input or output of a particular group is on.

Command Format: [GkUi]

Gk

= group number (k = # from 1-9)

Ui

= unit number (i = # from 0-9)

Example:

In unit ID0, if group 1 has DA Cards with outputs 1 and 2 on, while group 2 has SW Cards with input 2 on:

9

Image 10
Contents MT104-108 Table of Contents Precautions / Safety Warnings Cleaning Precautions / Safety WarningsInstallation GeneralAbout Your MULTI-TASKER Technical Specification MT104-108Product Description Application Diagram Diagram 2 Block Diagram MT104-108Operation Installing Your MULTI-TASKERDescription of Commands VERC3U2MT104-108 Command Format CnUiCommand Format ONmCnUiP ONmCnUiS for a Single cardOFF Command Format OFFmCnUiPON…..F feedback OFFmCnUiS for a Single cardCommand Format WRCn…GkUi SW SwitchCommand Format HELPCnUi Command Format CLRGkUiHelp Summary of Commands VEROFF CLRAltinex Policy Troubleshooting GuideLimited WARRANTY/RETURN Policy Contact Information LED is not LIT