Altinex MT104-108 manual ON…..F feedback, Off, OFFmCnUiS for a Single card, OFF…..P sets path

Page 9

MULTI-TASKER™

Example:

There are two MT104-108cards in slots 6 and 7 of unit 3. Enable input 1 of card 6 and input 3 of card 7 simultaneously. Use the following commands:

[ON1C6U3P] [ON3C7U3P] [SW]

If "F" is included, use the [ONmCnUiPF] command or the [ONmCnUiFP] command.

[ON…..F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

Example:

[ON1C2U3F]: if path is not set

[ON1C2U3PF]: if path is set

5.[OFF]

This command disables one input of a single card or a group of cards.

[OFFmCnUiS]: for a SINGLE card

This command disables input “m” or all inputs. The command [OFFC5CnUi], turns OFF all inputs of the MT104-108 card.

m

= Input (m = 1 to 7, input 7 is internal

Cn

= Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID number (i = 0 to 9)

S

= saves command to memory

Example:

Card 5 of unit 3 has input 1 ON. Card 6 of unit 3 has input 5 ON. The following commands can be used to turn OFF the inputs on both cards simultaneously.

1)[OFF1C5U3]: Turns OFF input 1.

2)[OFF3C6U3]: Turns OFF input 3.

3)[OFFmGkUiS]: for a group of cards

This command disables input "m" for each card in group "k" of unit "i".

m

= Input (m = 1 to 7, 7 is internal)

Cn

= Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID number (i = 0 to 9)

S

= saves command to memory

Example:

1)[OFF1G1U1]: Turns OFF input 1 for each card in group 1 of unit 1.

2)[OFFG1U1]: Turns OFF all inputs for each card in group 1 of unit 1.

[OFF…..P]: sets path

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. Then, all connection may be made simultaneously.

Command Format: [OFFmCnUiP]

m

= Input (m = 1 to 7, 7 is internal)

Cn

= card ID (n = slot # from 1 to max slots)

Ui

= Unit ID number (i = 0 to 9)

P

= path

Example:

There are two MT104-108cards in slot 6 and 7 of unit 3. Enable input 1 of card 6 and input 3 of card 7 simultaneously. Use the following commands:

[OFF1C6U3P] [OFF3C7U3P] [SW]

If "F" is included, use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command.

[OFF…..F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

Example:

 

[OFF1C2U3F]:

if path is not set

[OFF1C2U3PF]:

if path is set

8

Image 9
Contents MT104-108 Table of Contents Precautions / Safety Warnings Installation Precautions / Safety WarningsCleaning GeneralMT104-108 About Your MULTI-TASKER Technical SpecificationProduct Description Application Diagram MT104-108 Diagram 2 Block DiagramDescription of Commands Installing Your MULTI-TASKEROperation VERC3U2Command Format ONmCnUiP Command Format CnUiMT104-108 ONmCnUiS for a Single cardON…..F feedback Command Format OFFmCnUiPOFF OFFmCnUiS for a Single cardCommand Format HELPCnUi SW SwitchCommand Format WRCn…GkUi Command Format CLRGkUiOFF Summary of Commands VERHelp CLRLimited WARRANTY/RETURN Policy Contact Information Troubleshooting GuideAltinex Policy LED is not LIT