Example:
One
MT104-108 690-0160-002
2.[C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = card ID (n = # from 1 to max slots)
Ui = unit ID (i = from 0 to 9) ( refer to the
[ONmCnUiS]: for a SINGLE card
This command enables input “m” and disables all other inputs.
[ONmCnUi]: enables input
Default when plugged in = Input 1 is ON
m = Input number (m = 1 to 7, 7 is internal)
Cn | = Card ID (n = slot # from 1 to max slots) |
Ui | = Unit ID number (i = 0 to 9) |
S | = saves command to memory |
Example:
If all of the inputs on the
1) [ON1C5U3]: Turns ON input 1. |
Example:
An
ON: 1 C02
card is in slot #2 of unit 3 and Sending the command [C2U3] following feedback from the
2) [ON3C5U3]: Turns ON input 3 (input 1 is |
now OFF). |
[ONmGkUiS]: for a GROUP of cards
This command enables input "m" for each card in group "k" of unit "i".
[ONmGkUi]: enables a group of inputs
ON: 1= input 1 is ON
C02 = card is in slot 2
If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback.
3.[CnS]
This command saves the current status of the card's input selection configuration. This configuration will be restored after system is reset or powered off then on.
Cn | = card number |
S | = save configuration |
If Inputs 1,2,3,4,5 and 6 are enabled, the feedback after sending the command [C4S], for slot 4, would be:
ON:1,2,3,4,5,6 C04 Saved
4.[ON]
This command enables one input of a single card or a group of cards.
m | = Input (m = 1 to 7, input 7 is internal) |
Gk | = group number (k = # from |
Ui | = unit number (i = # from |
S | =saves command to memory |
Example:
[ON1G1U1]: Turns ON input 1 for each card in group 1 of unit 1.
[ON…..P]: sets path
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded and then all switched at the same time.
Command Format: [ONmCnUiP]
m | = Input number (m = 1 to 7, 7 is internal) |
Cn | = card ID (n = slot # from 1 to max slots) |
Ui | = Unit ID number (i = 0 to 9) |
P | = path |