American Power Conversion Automatic Disconnect Switch user manual Limited Warranty

Page 13

Troubleshooting, Service, Contact, Warranty and Regulatory Information

Troubleshooting, Service, Contact, Warranty and Regulatory Information

Troubleshooting

Use this chart to solve minor installation and operation problems. Refer to the APC Web, site www.apc.com with complex problems.

Problem and/or Possible Cause

 

Solution

 

 

Unit is on and the 220 V Normal LED is not illuminated

 

 

The unit is not wired properly.

 

Check that the input and output wiring are not reversed.

 

 

 

The circuit breaker is tripped.

 

Reset the circuit breaker.

 

 

 

The 220 V power is outside the specified

 

Check that the 220 V power is within specified limits. Refer to Specifications in this

limits.

 

manual.

 

 

Unit is on and the Local 63 V Fault LED is illuminated

 

 

The unit is not connecting power to the cable

 

Check that the coax connections are not reversed.

system.

 

Check that the FRP/FLM output is within specified limits. Refer to Specifications in

 

 

 

 

this manual.

 

 

Secondary unit will not switch to Remote power when the Test button is pressed

 

 

Remote power system is not functioning.

 

This is normal operation. Verify that the Remote power system is working.

 

 

 

Primary unit is indicating Remote power

 

 

 

Primary unit was powered up after the

 

This is normal operation. Press the Reset button on the secondary unit to transfer

secondary unit.

 

power to the primary unit.

 

 

The primary FRP/FLM output is not within specified limits. Refer to Specifications in

 

 

this manual.

 

 

 

Limited Warranty

American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support.

Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase.

EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Broadband Automatic Disconnect Switch User Manual

13

Image 13 Contents
Broadband Automatic Disconnect Switch Page Specifications SafetyIntroduction About this unitUnpack InstallationSchematic Overview of the Automatic Disconnect Switch System Utility Power Connections Mount the Automatic Disconnect Switch on the WallHardwire the Automatic Disconnect Switch Cable System Connections Connector InstallationCoax Connection   Cable Modem Connection Primary/Secondary Access Panel Indicators and ControlsOperation Start UpPrimary Status Cable ModemSecondary Status Problem and/or Possible Cause Solution Limited WarrantyFCC Compliance Notice Service
Related manuals
Manual 14 pages 29.01 Kb