Advanced Options
Select “Adv Option”, press [OK], the following appears:
Adv Option | ▼ |
►Reset Opts. |
|
Del AttLogs |
|
Clear All Data |
|
Clr Admin Pri |
|
Show Score | N |
Match Thr | 35 |
Mst Input ID | N |
1:1 Thr | 15 |
Voice | Y |
Upd Firmware |
|
Work Code | NO |
Adj VOL(%) | 67 |
Press [▲/▼] to scroll up or down to select the option.
Reset Opts.: Restore all setup values to factory defaults.
Delete AttLogs: Delete all transaction logs.
Clear All Data: Delete all users and logs. (Note: You will lose all information stored on the terminal.)
Clr Admin Pri: Change all privilege levels to User.
Show Score: Show the degree to which a fingerprint reading matches the stored template. 0 is the lowest score (no match) and 50 is the highest score (perfect match).