4.6 Firmware functions (version query, mouse restore and reset)

For technical support purposes, it may be necessary to find the firmware release version for the control software in your SmartView. For example, if the release version is v1.02 the response shown to F1(enter) will be a brief display of the digit ‘1’, then F2(enter) will be a brief display of the digit ‘0’, then F3(enter) will be a brief display of the digit ‘2’. You can reset all of the configured options back to the factory default states by typing F8. Use options F5 and F6 to restore mouse function on disconnected PS/2 CPU mouse connections. See section 2.9 for full details.

F1 - Display firmware first digit

F2 - Display firmware second digit

F3 - Display firmware third digit

F5 - Restore PS/2 mouse function to the currently selected CPU’s mouse port F6 - Restore IntelliMouse function to the currently selected CPU’s mouse port

F8 - Reset all configurations to factory default settings. An ‘r’ will show briefly on the display to confirm that the reset has been completed.

4.7 Display appearance options

Options are available to change the colour scheme of the On-Screen Display and the time that the confirmation message remains on the screen after a channel has been selected.

D1 - Menu appears with magenta / blue background and green highlight (default) D2 - Menu appears with red / blue background and green highlight

D3 - Menu appears with blue / black background and light blue highlight

D4 - Confirmation message remains on screen for standard time period (default) D5 - Confirmation message remains on screen for short time period

D6 - Confirmation message remains on screen for extended time period

SmartView

Installation and Use

Page 34

Image 34
Contents Warranty Safety informationAbout this manual Radio Frequency Energy European EMC directive 89/336/EECContents SmartView configuration options AppendicesKey features IntroductionPackage contents Product information SmartView SV8PROModels SmartView SV4PROSmartView SV12PRO SmartView SV16PRO Installation What you will needConnecting your devices Mounting the SmartViewTo enter configure mode at power on Configuring your PCsConfiguring the SmartView To enter configure mode whilst the SmartView is runningSummary of SmartView configuration options H2f EfU4 SmartView channels are switchable using 3 button mouse Other useful installation information Re-enabling a disconnected PS/2 mouse SmartView Installation and Use Front panel keys and remote controller Using the SmartViewPower on status Status lightsAuto key Auto and Select keys pressed together Lock functionStatus display Using the dual control ports a and B Keyboard hotkey control‘HOTKEYs’ and ‘1 then 2’ selects channel ‘HOTKEYs’ and ‘1 then 0’ selects channel‘HOTKEYs’ and ‘1 then 1’ selects channel ‘HOTKEYs’ and ‘1 then 3’ selects channelOn Screen Menu control SmartView Installation and Use Editing a computer on the menu list Deleting a computer from the menu listSelecting a computer on the menu list Cascading SmartViews Mouse controlRS232 control Summary of keys used by the menu and their functionSmartView Installation and Use Typical cascade of two SmartViews Screen saver time delay Autoscan ‘lock on’ mode and delay timeSmartView Installation and Use Mouse mode and mouse switching of channels Keyboard hotkey combination Firmware functions version query, mouse restore and reset Display appearance optionsSetting a security password OFREDgExit configure mode Cascade query codeCable specifications Appendix A. Cable and connector specificationsCable specification A1. Keyboard, monitor and mouse to SmartViewA3. Expansion port pin assignments Problem Appendix B. Problem SolvingAction Mouse causes channel to change Problem SmartView Installation and Use SmartView Installation and Use SmartView Installation and Use