Adder Technology SmartView warranty Cascade query code, Exit configure mode

Page 36

4.9 Cascade query code

The SmartViews use a special ‘query code’ to detect whether or not they are connected to another SmartView. By default your SmartView Pro uses query code AD. SmartView Pro units with firmware versions less than 1.09 and SmartView units with firmware version less than 1.18 used query code EF. This was found to conflict with a small number of other (rare) devices that used the same query code so an alternative query code was provided to ensure compatibility. Either query code may be used but you should make sure that all cascaded SmartView units are set to use the same query code. If any of the cascaded SmartView Pros have firmware versions less than 1.09 then the cascade query code for all the SmartView Pros should be set to EF.

L7 – Cascade query code = AD (default)

L8 – Cascade query code = EF

4.10 Exit configure mode

When you have finished configuring any special options, simply type ‘E’ followed by (enter) to exit configure mode and return to normal operation mode. The attached computers can now be switched on.

SmartView

Installation and Use

Page 36

Image 36
Contents Safety information WarrantyAbout this manual Radio Frequency Energy European EMC directive 89/336/EECContents SmartView configuration options AppendicesKey features IntroductionPackage contents Product information SmartView SV8PROModels SmartView SV4PROSmartView SV12PRO SmartView SV16PRO Installation What you will needConnecting your devices Mounting the SmartViewConfiguring your PCs Configuring the SmartViewTo enter configure mode at power on To enter configure mode whilst the SmartView is runningSummary of SmartView configuration options H2f EfU4 SmartView channels are switchable using 3 button mouse Other useful installation information Re-enabling a disconnected PS/2 mouse SmartView Installation and Use Using the SmartView Power on statusFront panel keys and remote controller Status lightsAuto key Auto and Select keys pressed together Lock functionStatus display Using the dual control ports a and B Keyboard hotkey control‘HOTKEYs’ and ‘1 then 0’ selects channel ‘HOTKEYs’ and ‘1 then 1’ selects channel‘HOTKEYs’ and ‘1 then 2’ selects channel ‘HOTKEYs’ and ‘1 then 3’ selects channelOn Screen Menu control SmartView Installation and Use Deleting a computer from the menu list Editing a computer on the menu listSelecting a computer on the menu list Mouse control RS232 controlCascading SmartViews Summary of keys used by the menu and their functionSmartView Installation and Use Typical cascade of two SmartViews Screen saver time delay Autoscan ‘lock on’ mode and delay timeSmartView Installation and Use Mouse mode and mouse switching of channels Keyboard hotkey combination Firmware functions version query, mouse restore and reset Display appearance optionsSetting a security password OFREDgExit configure mode Cascade query codeAppendix A. Cable and connector specifications Cable specificationCable specifications A1. Keyboard, monitor and mouse to SmartViewA3. Expansion port pin assignments Appendix B. Problem Solving ProblemAction Mouse causes channel to change Problem SmartView Installation and Use SmartView Installation and Use SmartView Installation and Use