Adder Technology TS4 manual How does Synchrony work?, Synchrony configuration tips

Page 4

How does Synchrony work?

Synchrony is a small software utility that runs on each of your computer

Synchrony configuration tips

 

systems and continually tracks the current mouse cursor position. One system is

In combination with the installation instructions provided with the Synchrony

designated as the ‘primary’ and the other systems use standard network links to

utility, please consider these configuration tips:

 

report their mouse cursor information back to it.

• You are recommended to use a native serial port or third-party serial card on

The primary system has an extra communication link directly to the Adder TS4

the primary system. USB to serial adapters will work, but won’t provide such

switch. When the Synchrony utility detects that the cursor has moved over the

a rapid switching action between systems.

 

edge of a screen boundary, it instructs (via the primary computer) the Adder

• Option switch 5 is used to place the Adder TS4 into Synchrony mode,

TS4 to switch the common keyboard and mouse through to the appropriate

however, the setup switches are only consulted during the power on phase,

computer.

or when the TS4 is reset using option switch 8. Moving option switch 5

The Adder TS4 and Synchrony combination minimises any potential security risks

whilst the unit is on will have no effect.

 

in two important ways:

• For each system, the screen name that you enter in the Synchrony setup

• The network messages flowing between the systems contain only benign

must be the name that identifies the system on the network (it cannot be

cursor positioning reports.

random). In Windows this can be found in My Computer > Properties >

• All keyboard and real mouse data flow only through the direct keyboard and

Computer Name. Alternatively, you can discover the screen name by running

the Synchrony software and selecting “Advanced”. The computer name of

mouse connections via the Adder TS4, not via the network.

the current computer is then shown in the Screen Name field.

The Synchrony utility provides straightforward configuration in which you

 

 

can define the connected systems, their network identities and their relevant

 

 

switching scenarios. The primary system runs Synchrony in server mode whereas

 

Full instructions on how to install

the other systems run Synchrony within its client mode.

 

 

and configure Synchrony are

 

 

Cursor position data sent to primary system via standard network links

included with the utility which

can be downloaded from this

 

 

 

 

location:

 

 

www.adder.info/synchrony

The primary

 

 

 

 

 

system runs

PC1

PC2

PC3

PC4

Cursor currently

the Synchrony

(PRIMARY)

 

 

 

active on system

utility in Server

 

 

 

 

PC4

mode. All

 

 

 

 

 

other systems

 

 

 

 

 

run the utility

 

 

 

 

 

in Client mode.

 

 

 

 

 

 

 

 

 

 

Common keyboard and mouse

 

 

 

 

 

links switched through to the

 

 

 

 

 

currently active system (PC4)

ADDER

SYSTEM

www.adder.comSELECT

Switching commands sent from primary system via special serial link

    

Image 4
Contents Adder TS4 Contents Welcome IntroductionSynchrony configuration tips How does Synchrony work?Standard items Additional and optional itemsLocations InstallationMounting Making connections System connectionsTo connect a system PS/2-style connections To connect a system USB-style connectionsOptional power supply connections Remote control connectionsKeyboard and mouse connections Synchrony connections To connect the Synchrony serial link cableConfiguration switch settings Recognising an IntelliMouse-style mouse To restore mouse operation when hot pluggingRecognising an IntelliMouse driver System readout OperationSelecting systems Setting or changing a password Configuration optionsChanging hotkeys Resetting and restoring default settings Mouse button switching modesAll channel/active channel cycling Upgrading To upgrade the Adder TS4To discover the current firmware version Troubleshooting Upgrade cable pin outFurther information Getting assistanceSafety information WarrantyEmissions and Immunity European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementUnited States of America