3Com 2226 PLUS manual Rack-Mounting or Free-Standing, Using the Mounting Kit

Page 16

16INSTALLING THE SWITCH

Alternatively, the Switch can be rack-mounted in a wiring closet or equipment room. A mounting kit, containing two mounting brackets and four screws, is supplied with the Switch.

When deciding where to position the Switch, ensure that:

It is accessible and cables can be connected easily.

Cabling is away from sources of electrical noise. These include lift shafts, microwave ovens, and air conditioning units. Electromagnetic fields can interfere with the signals on copper cabling and introduce errors, therefore slowing down your network.

Water or moisture cannot enter the case of the unit.

Air flow around the unit and through the vents on the side of the case is not restricted (3Com recommends that you provide a minimum of 25 mm (1 in.) clearance).

The air is as free from dust as possible.

Temperature operating limits are not likely to be exceeded. It is recommended that the unit is installed in a clean, air conditioned environment.

It is always good practice to wear an anti-static wrist strap when installing network equipment, connected to a ground point. If one is not available, try to keep in contact with a grounded rack and avoid touching the unit's ports and connectors, if possible. Static discharge can cause reliability problems in your equipment.

Rack-Mounting or Free-Standing

The unit can be mounted in a 19-inch equipment rack using the mounting kit or it can be free standing. Do not place objects on top of the unit or stack.

CAUTION: If installing the Switch in a free-standing stack of different size Baseline or Superstack 3 units, the smaller units must be installed above the larger ones. Do not have a free-standing stack of more than six units.

Using the Mounting Kit

The Switch is supplied with two mounting brackets and four screws. These are used for rack mounting the unit. When mounting the unit, you should take note of the guidelines given in “Positioning the Switch” on

page 15.

The Switch is 1U (1.7 inches) high and will fit in a standard 19-inch rack.

CAUTION: Disconnect all cables from the unit before continuing. Remove the self-adhesive pads from the underside of unit, if already fitted.

To rack-mount the Switch:

1Place the unit the right way up on a hard, flat surface with the front facing towards you.

2Locate a mounting bracket over the mounting holes on one side of the unit.

Image 16
Contents Baseline Switch Plus 3C16475CS3Com Corporation 350 Campus Drive Marlborough MA USA Contents Snmp Glossary Regulatory Notices Index Page About this Guide ConventionsDocumentation Comments Product RegistrationOverview of the Baseline Switch Features and CapabilitiesAutosensing of MDI/MDIX Connections Autonegotiating 10/100 Mbps PortsPhysical Features Front PanelGigabit Combo Ports RJ-45/SFP 10/100BASE-TX Ports Power LED Rear PanelPackage Contents Positioning the Switch Before You BeginUsing the Mounting Kit Rack-Mounting or Free-StandingMontagesatz Anweisungen Placing Units On Top of Each OtherSupplying Power to the Switch Checking for Correct OperationApproved SFP Transceivers Using SFP TranceiversInserting an SFP Transceiver Removing an SFP Transceiver Inserting an SFP TransceiverPerforming Spot Checks Installing the Switch Requirements for Accessing the Web Interface Running the Discovery ApplicationWelcome screen of Discovery appears Logging On to the Web Interface Discovered Devices ScreenNavigating the Web Interface MenuLists the available items on the menu Menu Item Description Buttons Port StatusDhcp Assigned IP Address Accessing the Interface Without Using DiscoveryManually Assigned Static IP Address Configuration Overview Device Summary InformationDevice View Polling IntervalAdministration Settings Modifying the IP Address SettingsAutomatic IP Configuration Color KeyIP Setup To set the IP address for the SwitchBackup Configuration Restore ConfigurationFirmware Upgrade Upgrade ScreenReboot InitializeSystem Access User SummaryCreate User Modify UserSystem Time Remove UserSummary SetupSnmp Add Configuring VLANs Snmp RemoveVlan Modify Vlan Modify PortRename Modify Port ScreenPort Detail RemoveVlan Detail Sample Vlan Configurations Forwarding Tagged/Untagged FramesSetting Up Two VLANs on the Same Switch Setting Up Vlan Across Two SwitchesTagged Vlan Configuration Spanning TreeSpanning Tree Screen Igmp Query Igmp SnoopingBroadcast Storm Broadcast Storm Setup Screen Configuring Port Settings AdministrationPort Administration Detail Screen DetailPort Administration Setup Screen Speed/Duplex for 1000 Mbps ConnectionsLink Aggregation Guidelines for Creating TrunksCreate ModifySpanning Tree per Port Link Aggregation Remove ScreenSpanning Tree Summary Screen Spanning Tree Detail Screen Port Mirroring Setup Screen Port MirroringQoS VoIP Traffic Settings StatisticsPort Setup QoS VoIP Summary ScreenQoS Port Setup Screen OUI SummaryRadius Client SecurityOUI Modify Configure Radius Client Detail Screen802.1X Settings Radius Client Configure Screen802.1X Summary Screen Security Monitoring Cable DiagnosticsAddress Table Diagnostics Cable Diagnostic Summary ScreenConfiguring the Switch Troubleshooting Resetting to Factory DefaultsSolving LED Issues Forgotten PasswordForgotten Static IP Address Fiber cable is connected, but the Module Active LED is off Link/Activity LED is on, but network performance is poorIf the Problem Persists All ports appear to show continual activityTroubleshoot Online Access Software Downloads Purchase Value-Added ServicesRegister Your Product Telephone Technical Support and Repair Contact UsCountry Telephone Number Latsupportanc@3com.com Related Standards EnvironmentalPhysical ElectricalAppendix B Technical Information Safety Information Important Safety InformationAppendix C Safety Information Auto-negotiation 1000BASE-TBandwidth Category 3 Cables Category 5 CablesCategory 5e Cables Category 6 CablesFull Duplex Half DuplexIeee 802.1D Ieee 802.1QLayer Link AggregationMAC Address NetworkSwitch ServerSubnet Address Subnet MaskVlan Regulatory Notices Page Index NumbersIndex

2226 PLUS specifications

The 3Com 2226 PLUS is a robust network switch designed to meet the increasing demands of modern networking environments. Its ability to provide reliable connectivity and support for various technologies makes it an ideal choice for small to medium-sized businesses. This switch features 24 10/100 Mbps Ethernet ports, which allow for fast and efficient data transfer, enabling businesses to enhance their network performance significantly.

One of the standout technologies employed in the 3Com 2226 PLUS is its support for auto-negotiation. This feature automatically detects the speed and duplex capabilities of connected devices, ensuring optimal performance and minimizing configuration errors. This capability simplifies network management, allowing IT professionals to focus on other critical tasks rather than troubleshooting connectivity issues.

In addition to its impressive port offerings, the 3Com 2226 PLUS incorporates a range of Layer 2 switching features. These include support for Virtual LANs (VLANs), which enable businesses to segment their networks for improved security and efficiency. By implementing VLANs, organizations can isolate sensitive data traffic from less secure networks, enhancing overall data protection.

The switch also supports Spanning Tree Protocol (STP), which helps prevent loops in network topology. This is crucial in environments with multiple switches, as it maintains a stable network while ensuring redundancy. If a primary link fails, STP allows for a backup path to be automatically activated, ensuring minimal disruption in connectivity.

Power over Ethernet (PoE) capabilities are another significant feature of the 3Com 2226 PLUS. This technology allows the switch to deliver power to connected devices, such as IP cameras and VoIP phones, eliminating the need for additional power supplies and reducing cable clutter.

In terms of management, the 3Com 2226 PLUS supports both simple web-based configuration and SNMP (Simple Network Management Protocol), providing network administrators with flexibility in how they manage their network infrastructure.

Built with reliability in mind, the switch comes equipped with features like store-and-forward switching, error checking, and a sturdy design suitable for deployment in various environments.

Overall, the 3Com 2226 PLUS combines essential features and advanced networking technologies, making it a versatile and dependable solution for businesses looking to upgrade or establish their network infrastructure.