SEQUENCE OF OPERATIONS
IMPINGER II ADVANTAGE
MODEL
MODEL
POWER SUPPLY | Electrical power is supplied to the oven by a three conductor cordset. Voltage |
| from the black conductor to the white conductor is 120 VAC. The white |
| conductor is neutral. The green conductor is ground. |
CONTROL BOX AUTO | When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°C), |
| the |
COOL DOWN | interrupt power to the fans when the control box temperature falls to 100°F ± 3° |
| (37.8°C ± 1.7°C). |
MAIN FAN CIRCUIT | Power is permanently supplied, through a 10A fuse, and through a normally |
| closed control box |
| Power is also supplied to the normally open cooling fan thermostat. Closing the |
| main fan switch supplies 120 VAC to the main fan motor, the cooling fan motor, |
| the primary of the temperature display transformer, the heat and conveyor |
| circuits. |
BURNER CIRCUIT | Closing the main fan switch supplies 120 VAC to the burner blower motor. 120 |
| VAC is also supplied, through the normally closed oven cavity |
| the main fan centrifugal switch (this switch closes when main fan reaches |
| approximately 1600 RPM) to the electronic temperature control and to the |
| primary of the burner transformer. |
IGNITION CONTROL | The ignition control operates on both 24 VAC and 120 VAC. When the control is |
| energized by 24 VAC from the transformer, 120 VAC is switched by the ignition |
| control to the hot surface ignitor for 45 seconds for the hot surface ignitor warm |
| up. The ignitor glows red, 24 VAC is switched to the gas valve which opens and |
| ignition should now occur. |
TEMPERATURE CONTROL | When the centrifugal switch of the main fan motor closes, power is applied to the |
| temperature control. The 1K ohm temperature pot is adjusted to desired |
| temperature. The thermocouple will provide varying millivolts to the temperature |
| controller. The temperature controller supplies 120 VAC to the solenoid valve at |
| intermittent intervals to maintain desired temperature. The heat lamp is |
| energized with the solenoid valve. |
CONVEYOR DRIVE | Closing the on/off switch supplies 120 VAC to the motor control board. AC volts |
| are converted to DC volts and are supplied to the conveyor motor at terminals A+ |
| and |
| Adjustment of the speed control potentiometer will change resistance at terminals |
| P1 and P2 varying the DC voltage to the motor. The speed of the conveyor |
| motor will increase or decrease as the DC voltage from the board increases or |
| decreases respectively. |
NOTE: | The conveyor control uses a sensor and magnet, mounted on the conveyor |
| motor that senses the motor speed. Any change in motor load (±RPM) is |
| detected by the sensor and the voltage to the motor is adjusted accordingly. |
Temperature Display | Closing the switch supplies 120 VAC to the primary of the temperature display |
| transformer. The secondary of this transformer supplies 12 VAC to the temperature |
| display. The thermocouple supplies D.C. millivolts to the temperature display. The |
| display converts this millivolt reading to a temperature reading. |
Impinger II | 3 |