Temp. display inoperative | Display Transformer | Measure the transformer primary for a nominal 120 |
|
| VAC input, if voltage is not present, trace wiring back |
|
| to the oven power source. Measure the secondary |
|
| output, which will normally be |
|
| across terminals 1 and 3 on the time/temp. display |
|
| should read |
|
| should be 1/2 the voltage reading to |
|
| above secondary readings are not achieved, replace |
|
| transformer. |
| Temp. Display | If proper voltage is present at terminals 1, 2, and 3 |
|
| on temperature display, but the display is not lighted, |
|
| recheck all connections for tightness. If temperature |
|
| display is still not operating, replace the temperature |
|
| display. |
Temp. Display inaccurate, | Thermocouple | Place the thermocouple of a pyrometer into the |
erratic or inoperative |
| center of the top finger. Be sure the tip of the |
|
| thermocouple is not touching metal, it must sense air |
|
| temperature only. The pyrometer will indicate oven |
|
| temperature. Measure DC millivolts of thermocouple |
|
| at the temperature display. See thermocouple chart |
|
| on page 19 for proper readings. Replace |
|
| thermocouple if proper readings are not achieved. If |
|
| readings are correct on the thermocouple, replace |
|
| temperature display. |
12 | Impinger II – Advantage Service Manual - Domestic |