Renesas HS2633ECH61H user manual Installing the MCU to the User System

Page 23

Section 3 Installing the MCU to the User System

CAUTION

1.Check the location of pin 1 before inserting.

2.Use the screwdriver provided for tightening screws.

3.The tightening torque must be 0.054 N•m or less.

If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder.

4.If the MCU does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder the IC socket if necessary.

Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as shown in figure 9. After inserting the MCU, fasten the socket cover with the provided four screws (M2 x 6 mm). Take special care, such as manually securing the IC socket soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting the components.

14

Image 23
Contents H8S/2633 Group QFP-128 User System Interface Cable Page Important Information Limited Warranty Figures Limited Anticipation of Danger Safety Parts Preface Contents Configuration HS2633ECH61H User System Interface Cable HS2633ECH61H Components Connection Procedures Connecting User System Interface Cable to Emulator Station Connecting User System Interface Cable to User System Check the location of pin 1 before inserting Fastening Cable Head Connecting User System Interface Cable to User System Fastening Cable Body Recommended Dimensions for User System Mount Pad Dimensions for User System Interface Cable Head Page Installing the MCU to the User System Installing MCU to User System Clock Oscillator Circuits Verifying OperationUser System Interface Cable Location Example H8S/2633 Group QFP-128 User System Interface Cable REJ10B0085-0500H