Renesas HS2633ECH61H user manual User System Interface Cable Location Example

Page 26

Section 5 Notice

1.Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket.

2.The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.

3.This user system interface cable is specifically designed for the HS2633EPI61H emulator. Do not use this cable with any other emulator station.

4.To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable.

5.While the emulator station is connected to the user system with the user system interface cable, force must not be applied to the cable head. Place the emulator station, user system interface cable, and user system as shown in the example in figure 11.

Figure 11 User System Interface Cable Location Example

6. The P1 jumper socket is used for testing. Do not remove the inserted jumper pin.

Figure 12 P1 Jumper Socket

17

Image 26
Contents H8S/2633 Group QFP-128 User System Interface Cable Page Important Information Limited Warranty Figures Limited Anticipation of Danger Safety Parts Preface Contents Configuration HS2633ECH61H User System Interface Cable HS2633ECH61H Components Connection Procedures Connecting User System Interface Cable to Emulator Station Connecting User System Interface Cable to User System Check the location of pin 1 before inserting Fastening Cable Head Connecting User System Interface Cable to User System Fastening Cable Body Recommended Dimensions for User System Mount Pad Dimensions for User System Interface Cable Head Page Installing the MCU to the User System Installing MCU to User System Verifying Operation Clock Oscillator CircuitsUser System Interface Cable Location Example H8S/2633 Group QFP-128 User System Interface Cable REJ10B0085-0500H