Renesas HS2633ECH61H user manual Verifying Operation, Clock Oscillator Circuits

Page 25

Section 4 Verifying Operation

1.When using the E6000 emulator for the H8S/2633 group, turn on the emulator according to the procedures described in the H8S Family E6000 Emulator User's Manual (HS2000EPI61HE).

2.Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1.

3.The emulator connected to this user system interface cable supports two kinds of clock sources as the MCU clock: an emulator internal clock and an external clock on the user system. For details, refer to the Emulator Supplementary Information (HS2633EPI61HE).

To use the emulator internal clock

Select the clock in the emulator station as the system clock (φ ), by using the CLOCK command (emulator command).

To use the external clock on the user system

Select external clock t or t2 with the CLOCK command (emulator command). Supply the external clock from the user system to the emulator.

Connect a crystal oscillator to the EXTAL and XTAL terminals for the system clock (φ ), or input the external clock from the EXTAL terminal on the cable head.

Connect a crystal oscillator to the OSC1 and OSC2 terminals for the subclock, or input the external clock from the OSC1 terminal on the cable head.

The user system interface cable has the oscillator circuits shown in figure 10. For details, refer to section 23, Clock Pulse Generator, in the H8S/2633 Group Hardware Manual.

R1 1 M

HCU04

R5 3.3 M

 

R13 10 k

 

 

To E6000

 

R12 2.2 k

 

To E6000

 

 

 

 

HCU04

emulator

HCU04

 

HCU04

emulator

 

R6 470 k

HCU04

 

 

 

 

 

 

R2 270

OSC1 OSC2

 

 

 

 

 

 

EXTAL XTAL

 

 

 

 

System clock oscillator

Subclock oscillator

 

 

Figure 10 Clock Oscillator Circuits

16

Image 25
Contents H8S/2633 Group QFP-128 User System Interface Cable Page Important Information Limited Warranty Figures Limited Anticipation of Danger Safety Parts Preface Contents Configuration HS2633ECH61H User System Interface Cable HS2633ECH61H Components Connection Procedures Connecting User System Interface Cable to Emulator Station Connecting User System Interface Cable to User System Check the location of pin 1 before inserting Fastening Cable Head Connecting User System Interface Cable to User System Fastening Cable Body Recommended Dimensions for User System Mount Pad Dimensions for User System Interface Cable Head Page Installing the MCU to the User System Installing MCU to User System Clock Oscillator Circuits Verifying OperationUser System Interface Cable Location Example H8S/2633 Group QFP-128 User System Interface Cable REJ10B0085-0500H