Renesas HS2633ECH61H user manual Connection Procedures

Page 13

Section 2 Connection Procedures

2.1Connecting User System Interface Cable to Emulator Station

WARNING

Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.

1.Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.

2.The user system interface cable dedicated to the emulator must be used.

To connect the cable body to the emulator station, follow the instructions below.

1. Make sure the user system and emulator station are turned off.

CAUTION

When connecting or removing the user system interface cable, apply force only in the direction suitable for connection or removal, while making sure not to bend or twist the cable or connectors. Otherwise, the connectors will be damaged.

2.After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2).

4

Image 13
Contents H8S/2633 Group QFP-128 User System Interface Cable Page Important Information Limited Warranty Figures Limited Anticipation of Danger Safety Parts Preface Contents Configuration HS2633ECH61H User System Interface Cable HS2633ECH61H Components Connection Procedures Connecting User System Interface Cable to Emulator Station Connecting User System Interface Cable to User System Check the location of pin 1 before inserting Fastening Cable Head Connecting User System Interface Cable to User System Fastening Cable Body Recommended Dimensions for User System Mount Pad Dimensions for User System Interface Cable Head Page Installing the MCU to the User System Installing MCU to User System Clock Oscillator Circuits Verifying OperationUser System Interface Cable Location Example H8S/2633 Group QFP-128 User System Interface Cable REJ10B0085-0500H