Renesas HS2633ECH61H user manual Recommended Dimensions for User System Mount Pad

Page 20

2.3Recommended Dimensions for User System Mount Pad

Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-128 package (NQPACK128RD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.

17.00 ± 0.15

 

 

8.50

 

 

 

 

6.00

 

 

 

 

11.50

 

7.00

 

 

23.00 ± 0.15

3-

1.00

0.50

 

 

 

 

2.00 ± 0.10

 

 

 

0.50

 

0.25

 

 

 

Unit: mm

 

 

Tolerance:

± 0.10 mm

Figure 6 Recommended Dimensions for Mount Pad

11

Image 20
Contents H8S/2633 Group QFP-128 User System Interface Cable Page Important Information Limited Warranty Figures Limited Anticipation of Danger Safety Parts Preface Contents Configuration HS2633ECH61H User System Interface Cable HS2633ECH61H Components Connection Procedures Connecting User System Interface Cable to Emulator Station Connecting User System Interface Cable to User System Check the location of pin 1 before inserting Fastening Cable Head Connecting User System Interface Cable to User System Fastening Cable Body Recommended Dimensions for User System Mount Pad Dimensions for User System Interface Cable Head Page Installing the MCU to the User System Installing MCU to User System Verifying Operation Clock Oscillator CircuitsUser System Interface Cable Location Example H8S/2633 Group QFP-128 User System Interface Cable REJ10B0085-0500H