Powerware user manual Model ST-2400S Horsepower Computer System User Manual In the USA

Page 1

Model ST-2400S

Horsepower Computer System

User Manual

In the USA:

Star Test Dynamometer, Inc.

712 Thistlewood Court

Normal, IL 61761

Phone: (309) 826-1484

In Mexico, Central & South America: Negociaciones Fuentes S.A. DE CV Av. La Luz 4549 Col. Cortijo del Rio Monterey, N.L. Mexico 64890 Phone: 81.8349.1416

Manufacturered by:

Ries Labs, Inc.

2275 Raven Road

Farina, IL 62838

Phone: (618) 238-1400

eMail: admin@rieslabs.com

Image 1
Contents eMail admin@rieslabs.com Model ST-2400S Horsepower Computer System User Manual In the USAStar Test Dynamometer, Inc 712 Thistlewood Court Normal, IL Phone 309 Manufacturered by Ries Labs, Inc 2275 Raven Road Farina, IL Phone 618Table of Contents Description InstallationOperation Load Cell Rating Ft.-Lbs 10,000 CHECK readings using Ft.-Lbs. & Horsepower3750 2856Torque Set Switch Printer / Computer Interface Calibration Setup Software for the 2400S Software for the 2400S horsepower computerData Recording Software for the 2400S Dyno32 1. The instrument has been dropped or otherwise mistreated Calibration Procedure the torque arm of the dynamometer to insure that there is no force being applied to the load cell which would result in an inaccurate zero calibration. Remove the calibration access cover panel and set the calibration mode switch to the ZERO position. Also, be sure that the shunt resistor switch is set to the OFF position. At this time note that the RPM display of the unit should indicate “1111” and the POWER display should indicate “0000”. The TORQUE display indicates the TORQUE and should read near zero. If the torque indication is excessive plus or minus, the POWER display will read “EEEE” - which indicates that the zero offset of the load cell is excessive and that the ZERO calibration cannot proceed see calibration notes below. Otherwise, press and release the ENTER push-button switch to perform the zero calibration. At this point, the TORQUE display should indicate zero and the zero calibration procedure has been completed positive and negative torque to the unit and verify that the torque reading returns closely to the same value. A failure here indicates a likely problem with the dynamometer. Have the dynamometer checked by your dealer or dyno service person 45.3 K Ohm Shunt Resistor Torque Full scale Torque Ft.-Lbs64.14 128.3In Case of Difficulty E-MAIL ADMIN@RIESLABS.COMIn the USA STAR TEST DYNAMOMETER, INC 712 THISTLEWOOD COURT NORMAL, ILLINOIS PHONE 309 In Mexico, Central & South AmericaThere is likely no power to the unit. Check the power supply ProblemPower LED is not lit Power LED comes ONthe cable from the RPM pickup to the horsepower computer the RPM sensor connector to be sure that it is tight. CheckCheck the power supply to the horsepower computer. Have the horsepower computer checked