Powerware ST-2400S user manual Software for the 2400S horsepower computer

Page 9

When the horsepower computer is used with a companion personal computer, a standard (9 pin) RS-232-C extension cable is used to connect the two computers together. This extension cable is normally 10 feet long, but can be up to 50 feet long (and even longer if special “long range” RS- 232-C extension cables are used). The print rate and manual print switches serve to notify the personal computer which measurements are to be saved (or printed) in much the same way they are used when a printer is attached to the horsepower computer.

Software for the 2400S horsepower computer:

There are several software programs for the 2400S horsepower computer. These include:

Calibration Setup Software for the 2400S:

HpcOptionsW32 is software for the 2400S horsepower computer which is used to prepare the 2400S for calibration. This is done so that the 2400S will “know” the details of the method you will use to check the torque calibration of the unit. This “factory setup” is normally performed on the 2400S by your dealer prior to delivery of the 2400S to you so won’t have to.

If you change your calibration method or calibration tools, this program can be used to inform the 2400S of the changes so that subsequent torque calibrations will be accurate.

If you use a NIST traceable calibration method, this program must be used periodically (each time the load cell and the 2000S horsepower computer are sent in to have their NIST calibrations checked) to inform the 2400S of any changes to the load cell calibration or the internal 2400S traceable shunt resistor calibration.

HpcOptionsW32 is compatible with most Windows based computer systems including Win95, Win98, WinMe, Win2000 and WinXP.

Data Recording Software for the 2400S (Dyno32):

The Dyno32 software makes it easy to reproduce the 2400S horsepower displays on the screen of the personal computer for remote viewing, etc. There are also features for printing and recording (saving) your dyno measurements. Data printing and

9

Image 9
Contents eMail admin@rieslabs.com Model ST-2400S Horsepower Computer System User Manual In the USAStar Test Dynamometer, Inc 712 Thistlewood Court Normal, IL Phone 309 Manufacturered by Ries Labs, Inc 2275 Raven Road Farina, IL Phone 618Table of Contents Description InstallationOperation Load Cell Rating Ft.-Lbs 10,000 CHECK readings using Ft.-Lbs. & Horsepower3750 2856Torque Set Switch Printer / Computer Interface Software for the 2400S horsepower computer Calibration Setup Software for the 2400SData Recording Software for the 2400S Dyno32 1. The instrument has been dropped or otherwise mistreated Calibration Procedure the torque arm of the dynamometer to insure that there is no force being applied to the load cell which would result in an inaccurate zero calibration. Remove the calibration access cover panel and set the calibration mode switch to the ZERO position. Also, be sure that the shunt resistor switch is set to the OFF position. At this time note that the RPM display of the unit should indicate “1111” and the POWER display should indicate “0000”. The TORQUE display indicates the TORQUE and should read near zero. If the torque indication is excessive plus or minus, the POWER display will read “EEEE” - which indicates that the zero offset of the load cell is excessive and that the ZERO calibration cannot proceed see calibration notes below. Otherwise, press and release the ENTER push-button switch to perform the zero calibration. At this point, the TORQUE display should indicate zero and the zero calibration procedure has been completed positive and negative torque to the unit and verify that the torque reading returns closely to the same value. A failure here indicates a likely problem with the dynamometer. Have the dynamometer checked by your dealer or dyno service person 45.3 K Ohm Shunt Resistor Torque Full scale Torque Ft.-Lbs64.14 128.3In Case of Difficulty E-MAIL ADMIN@RIESLABS.COMIn the USA STAR TEST DYNAMOMETER, INC 712 THISTLEWOOD COURT NORMAL, ILLINOIS PHONE 309 In Mexico, Central & South AmericaThere is likely no power to the unit. Check the power supply ProblemPower LED is not lit Power LED comes ONthe cable from the RPM pickup to the horsepower computer the RPM sensor connector to be sure that it is tight. CheckCheck the power supply to the horsepower computer. Have the horsepower computer checked