Powerware ST-2400S In Case of Difficulty, Monterey, N.L. Mexico Phone, E-Mail Admin@Rieslabs.Com

Page 15

In Case of Difficulty:

The following is a troubleshooting guide that will help you to resolve any problems that may arise.

The Model 2400S Horsepower Computer contains no user serviceable parts. If it needs to be repaired you may return the unit to your dealer (who can also assist you with other repair problems such as problem diagnosis, replacement of the load cell, RPM pickup, other dynamometer repairs, etc.) or directly to:

In the USA:

STAR TEST DYNAMOMETER, INC.

712 THISTLEWOOD COURT

NORMAL, ILLINOIS 61761

PHONE: (309) 826-1484

In Mexico, Central & South America:

Negociaciones Fuentes S.A. DE CV

Av. La Luz 4549 Col. Cortijo del Rio

Monterey, N.L. Mexico 64890

Phone: 81.8349.1416

You may also return the 2400S Horsepower Computer and its power supply directly to the manufacturer for repair:

RIES LABS, INC.

2275 RAVEN ROAD

FARINA, ILLINOIS 62838

PHONE: (618) 238-1400

E-MAIL: ADMIN@RIESLABS.COM

Be sure to include a written description of the problems you are having with the unit, the name and phone number of a person to call if we need to discuss your problem with you, and return shipping instructions. If the unit is out of warranty, please also include a repair order and information about how you want the repaired unit returned to you. Ries Labs, Inc. does not open commercial accounts (charge accounts) for repair work. Ries Labs, Inc. accepts electronic payments (credit card or otherwise) using PayPal. You can sign up for your PalPal account by visiting http://www.paypal.com/ Sending your payment via PalPal is FREE, EASY, QUICK and SAFE.

Ries Labs, Inc. does not offer repair services for the other components of your dynamometer – only 2000S and 2400S horsepower computers, their power supply, and other items manufactured by Ries Labs, Inc.

15

Image 15
Contents Manufacturered by Ries Labs, Inc 2275 Raven Road Farina, IL Phone 618 Model ST-2400S Horsepower Computer System User Manual In the USAeMail admin@rieslabs.com Star Test Dynamometer, Inc 712 Thistlewood Court Normal, IL Phone 309Table of Contents Description InstallationOperation Load Cell Rating Ft.-Lbs 2856 CHECK readings using Ft.-Lbs. & Horsepower10,000 3750Torque Set Switch Printer / Computer Interface Software for the 2400S horsepower computer Calibration Setup Software for the 2400SData Recording Software for the 2400S Dyno32 1. The instrument has been dropped or otherwise mistreated Calibration Procedure the torque arm of the dynamometer to insure that there is no force being applied to the load cell which would result in an inaccurate zero calibration. Remove the calibration access cover panel and set the calibration mode switch to the ZERO position. Also, be sure that the shunt resistor switch is set to the OFF position. At this time note that the RPM display of the unit should indicate “1111” and the POWER display should indicate “0000”. The TORQUE display indicates the TORQUE and should read near zero. If the torque indication is excessive plus or minus, the POWER display will read “EEEE” - which indicates that the zero offset of the load cell is excessive and that the ZERO calibration cannot proceed see calibration notes below. Otherwise, press and release the ENTER push-button switch to perform the zero calibration. At this point, the TORQUE display should indicate zero and the zero calibration procedure has been completed positive and negative torque to the unit and verify that the torque reading returns closely to the same value. A failure here indicates a likely problem with the dynamometer. Have the dynamometer checked by your dealer or dyno service person 128.3 Full scale Torque Ft.-Lbs45.3 K Ohm Shunt Resistor Torque 64.14NORMAL, ILLINOIS PHONE 309 In Mexico, Central & South America E-MAIL ADMIN@RIESLABS.COMIn Case of Difficulty In the USA STAR TEST DYNAMOMETER, INC 712 THISTLEWOOD COURTPower LED comes ON ProblemThere is likely no power to the unit. Check the power supply Power LED is not litthe horsepower computer checked the RPM sensor connector to be sure that it is tight. Checkthe cable from the RPM pickup to the horsepower computer Check the power supply to the horsepower computer. Have