Powerware 6000 VA, 5000 manual Two-Year Limited Warranty US and Canada

Page 61

Chapter 10 Warranty

Two-Year Limited Warranty (US and Canada)

Powerware UPS Models: 3105, 3110, 3115, 9104, 9120, 9125, and FERRUPS® up to 3.1 kVA

WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Power Quality Corporation, a Delaware Corporation company (“Company”).

LIMITED WARRANTY: This limited warranty (this “Warranty”) applies only to the original End-User (the “End-User”) of any Powerware 3105, 3110, 3115, 9104, 9120, 9125, and FERRUPS up to 3.1 kVA Products (individually and collectively, the “Product”) purchased on or after June 1, 2004 and cannot be transferred. This Warranty applies even in the event that the Product is initially sold by Company for resale to an End-User.

LIMITED WARRANTY PERIOD: The period covered by this Warranty for Product installed [and currently located] in the fifty (50) United States, the District of Columbia, and Canada is twenty-four (24) months from the date of purchase.

WHAT THIS LIMITED WARRANTY COVERS: The warrantor warrants that the Product and battery (individually and collectively, the ”Warranted Items”) are free from defects in material and workmanship. If, in the opinion of Company, a Warranted Item is defective and the defect is within the terms of this Warranty, Company’s sole obligation will be to repair or replace such defective Warranted Item (including by providing service, parts and labor, as applicable), at the option of Company.

PROCEDURES FOR REPAIR OR REPLACEMENT OF WARRANTED ITEMS: The Warranted Item will be repaired or replaced at a Company site or such other location as determined by Company.

If the Warranted Item is to be replaced by Company, and the End-User supplies a credit card number or purchase order for the value of the replacement Product, Company will use commercially reasonable business efforts to ship (via standard ground shipment and at no cost to the End-User) the replacement Warranted Item to the End-User within one (1) business day after Company receives notice of the warranty claim. In such case, the End-User must return (at Company’s expense) the defective Warranted Item to Company in the same packaging as the replacement Warranted Item received by the End-User or as otherwise instructed by Company. If Company does not receive the defective Warranted Item, Company will either charge the End-User’s credit card, or send the End-User an invoice (which the End-User agrees to pay), for the value of the replacement Product.

If the Warranted Item is to be replaced by Company, but the End-User is unwilling or unable to supply a credit card number or purchase order for the value of the replacement Product, Company will use commercially reasonable business efforts to ship (via standard ground shipment and at no cost to the End-User) the replacement Warranted Item to the End-User within one (1) business day after Company receives the defective Product from the End-User.

In any case, Company will provide shipping instructions and will pay its designated carrier for all shipping charges for return of defective equipment and replacement of Warranted Items. Any returned Warranted Item or parts that are replaced may be new or reconditioned. All Warranted Items returned to Company and all parts replaced by Company shall become the property of Company.

EATON Powerware® 9125 Two-in-One UPS (5000/6000 VA) User’s Guide S 164201513 Rev B

55

www.powerware.com

 

Image 61
Contents Powerware 9125 Two-in-One UPS 5000/6000 VA User’s Guide FCC Part ICES-003 Class a EMC StatementsRequesting a Declaration of Conformity Special Symbols Table of Contents Specifications Troubleshooting Chapter Introduction Introduction R N I N G N G E RSikkerhedsanvisninger U T I O NR E Belangrijke Veiligheidsinstructies V a R S E LV a a R A R S C H U W I N GTarkeita Turvaohjeita G E L E TA R a R O I T U SN G E R Consignes de sécuritéR N U N G SicherheitswarnungenH T U N G R I C O L O Avvisi di sicurezzaV E R T E N Z a T E N Z I O N ER L I G Viktig SikkerhetsinformasionR S I K T I G I D a D O Regulamentos de SegurançaV E R T Ê N C I a R I G OПредупреждение ОпасноОсторожно L I G R O Advertencias de SeguridadV E R T E N C I a E C a U C I Ó NR a SäkerhetsföreskrifterK T I G T Inspecting the Equipment UPS SetupInstalling the UPS Internal Batteries Tower Setup Carefully position the cabinets upright see Figure Installing the Joining Brackets Top View EBM InstallationTypical EBM Installation Plug-Receptacle UPS Rear Panel Plug-Receptacle UPS InstallationRemote Emergency Power-off Installation Repo Connector Hardwired UPS Installation Hardwired UPS Rear Panel UPS Terminal Block Installation Installation Turning the UPS On Starting the UPS on BatteryTurning the UPS Off Initiating the Battery TestOperating Modes Transferring the UPS to Bypass ModeNormal Mode Battery Mode Bypass Mode Chapter Configuration Using Configuration Mode Configuration Mode LEDs and Options USB Port CommunicationCommunication Port Pin Assignment DB-9 Communication PortOptional X-Slot Cards Slot CardsCommunication When to Replace Batteries UPS and Battery CareReplacing Batteries How to Replace Extended Battery ModulesEBM Connections How to Replace Internal Batteries Testing New Batteries Recycling the Used Battery or UPS Chapter Specifications Electrical Output Weights and Dimensions Specifications Audible Alarms and UPS Conditions TroubleshootingTroubleshooting Guide Bypass Service and Support Two-Year Limited Warranty US and Canada WarrantyWarranty Ten-Year Pro-Rated Limited Warranty US and Canada Warranty Load Protection Guarantee US and Canada Warranty

6000 VA, 5000 specifications

The Powerware 5000 and 6000 VA uninterruptible power supplies (UPS) are robust solutions designed to provide high-performance protection for mission-critical IT equipment and infrastructure. These models are renowned for their reliability, efficiency, and advanced technologies, making them ideal for various applications, from small data centers to larger enterprise environments.

One of the standout features of the Powerware 5000 and 6000 VA is their modular design. This allows for easy scalability, enabling users to add battery modules as their power requirements grow. Such flexibility ensures that businesses can adapt their power solutions to match changing needs without investing in entirely new systems. Additionally, these UPS units offer redundant capabilities for critical components, ensuring higher availability and reducing the risk of downtime.

Efficiency is a crucial aspect of the Powerware series. With intelligent battery management technology, users can expect extended battery life and reduced operational costs. The Powerware 5000 and 6000 VA are designed to operate in various modes, including online, line-interactive, and eco-mode, which maximizes efficiency while maintaining high levels of power quality.

The UPS units also feature advanced monitoring and management capabilities. An intuitive LCD display provides real-time information regarding load levels, battery status, and system performance, enabling users to make informed decisions and respond swiftly to changing conditions. Furthermore, support for network management protocols allows for remote monitoring and management, making it easier to maintain system health without requiring physical access.

In terms of protection features, the Powerware 5000 and 6000 VA ingeniously incorporate surge protection, short circuit protection, and overload protection. This comprehensive approach safeguards critical equipment from power disturbances, ensuring uninterrupted operations.

Another notable characteristic is compatibility with various environments. The Powerware series is designed to fit seamlessly into both standard and compact spaces, benefiting data centers and telecom facilities.

Overall, the Powerware 5000 and 6000 VA uninterruptible power supplies stand out for their robust build quality, efficiency, and advanced power management capabilities. They are excellent choices for organizations seeking reliable, scalable, and efficient power protection solutions in an increasingly power-dependent world. They help ensure that businesses continue operating smoothly, even amidst potential power disruptions.