SUPER MICRO Computer 5017C-MTF, 5017C-MTRF manual ESD Precautions

Page 31

Chapter 4: System Safety

Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.

After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made.

4-3 ESD Precautions

!

Electrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards. The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD:

Use a grounded wrist strap designed to prevent static discharge.

Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.

Touch a grounded metal object before removing the board from the antistatic bag.

Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap.

Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or contacts.

When handling chips or modules, avoid touching their pins.

Put the serverboard and peripherals back into their antistatic bags when not in use.

For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.

4-3

Image 31
Contents Super Manual Revision 1.0c Release Date January 2 About This Manual PrefaceManual Organization Bios System SafetyAdvanced Serverboard Setup Advanced Chassis SetupPreface Table of Contents System Interface Advanced Chassis Setup Overview Chapter IntroductionMotherboard Features Server Chassis Features Intel C200 Chipset System Block Diagram Asia-Pacific Contacting SupermicroHeadquarters EuropePage Unpacking the System Chapter Server InstallationPreparing for Setup Choosing a Setup LocationServer Precautions Rack PrecautionsRack Mounting Considerations Ambient Operating TemperatureInstalling the Rear Inner Rails Installing the System into a RackIdentifying the Sections of the Rack Rails Installing Rear Inner Chassis Rails Installing the Rack RailsInstalling the Server into the Rack Installing the Server into a Telco Rack Accessing the Inside of the System Checking the Motherboard SetupChecking the Components Accessing the Inside of the System Checking the Drive Bay SetupChecking the Drives Checking the Airflow Providing PowerControl Panel Buttons ResetPower Chapter System InterfaceOverheat/Fan Fail Control Panel LEDsHard Drive Carrier LEDs Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsChapter Advanced Motherboard Setup Installing the LGA1155 Processor Processor and Heatsink InstallationPage Removing the Heatsink Installing a Passive CPU HeatsinkInstalling the Heatsink Connecting the Control Panel Connecting CablesConnecting Data Cables Connecting Power CablesI/O Ports Front Control Panel Header Pins JF1DDR3 Unbuffered ECC Udimm Memory Installing MemoryInstalling DIMMs Memory SupportPossible System Memory Allocation & Availability Installing Dimm into SlotPCI Slot/Card Configurations PCI Card InstallationAdding PCI Cards PCI Expansion SlotsMotherboard Details Number Jumper Description DefaultJumpers Number Headers/ConnectorsLED Indicators Number Connector DescriptionPower LED Connector DefinitionsATX Power Connector Processor Power ConnectorPower Button Reset ButtonOverheat OH/Fan Fail/Front UID LED Serial Ports Universal Serial Bus USBEthernet Ports External Speaker Fan HeadersChassis Intrusion ATX PS/2 Keyboard and PS/2 Mouse PortsWake-On-LAN Onboard Power LEDPower Supply I2C Connector Trusted Platform Module HeaderSgpio 0/1 Headers DOM PWR ConnectorSgpio 1/2 Headers Cmos Clear Jumper SettingsVGA Enable/Disable Explanation of JumpersWatch Dog Enable PCI Slot SMB EnableLAN Port Enable/Disable BMC Enable/DisableIpmi Dedicated LAN Onboard IndicatorsOnboard Standby Power LED LAN1/LAN2 LEDsSata Ports Sata Drive ConnectionsDriver Installation Display Screen Installing DriversSuperDoctor III Interface Display Screen Health Information SuperDoctorSuperDoctor III Interface Display Screen Remote Control Page Chapter Advanced Chassis Setup Chassis Front View Control PanelRemoving the Front Bezel Drive Bay Installation/RemovalSystem Fans System Fan FailureMounting a Drive in a Drive Carrier Accessing the Drive BaysSata Drive Installation Installing/Removing Sata DrivesMounting a Drive in a Carrier Sata BackplaneRemoving/Installing a Drive DVD-ROM Drive InstallationRemoving the Chassis Cover Power Supply Failure Power SupplyReplacing the Power Supply Removing the Power Supply Introduction Starting Bios Setup UtilityHow To Change the Configuration Data ChapterHow to Start the Setup Utility Main SetupProcessor System Time/System DateSystem Memory BOOT Feature Advanced Setup ConfigurationsProcessor & Clock Options Active Processor Cores Power TechnologyIntel AES-NI Intel Hyper Threading TechnologyChipset Configuration Pcie Maximum Payload Size Active State Power ManagementNorth Bridge Configuration VT-dIDE/SATA Configuration PCIe/PCI/PnP Configuration Super IO Device Configuration COM0/COM1/SOL Console Redirection Remote Access ConfigurationSerial Port 2 Mode Console Redirection SettingsCPU Temperature Display Mode Fan Speed Control ModeHardware Health Configuration ACPI Configuration Erase Event Log Smbios Event LogWhen Log is Full Event LogsIpmi Configuration BMC Network Configuration When SEL FullLog EFI Status Codes View FRU InformationBoot Options Priority Boot SettingsBoot Option #1, Boot option #2, Boot Option #3, etc Boot Sector Virus Protection Security SettingsAdministrator Password User PasswordDiscard Changes and Exit Restore DefaultsExit Options Save Changes and ExitRestore User Defaults Save As User DefaultsBoot Override Page Error Message Appendix a Bios Error Beep CodesBios Error Beep Codes Bios Error Beep CodesPage Appendix B System Specifications System Input Requirements WeightPower Supply System CoolingRegulatory Compliance

5017C-MTRF, 5017C-MTF specifications

Supermicro Computer has established itself as a leader in high-performance server solutions, and the Supermicro 5017C-MTF and 5017C-MTRF models exemplify the company's commitment to quality and innovation. These compact systems are designed for diverse applications, catering to both small and medium-sized enterprises as well as larger organizational needs.

The Supermicro 5017C-MTF and 5017C-MTRF come equipped with a powerful Intel Xeon E3-1200 v6 processor, offering remarkable processing capabilities that enable users to run demanding applications with ease. These systems support up to 64GB of ECC DDR4 memory, ensuring data integrity and reliability crucial for mission-critical workloads. Moreover, the implementations of Intel's turbo boost technology allow for dynamic performance enhancements, enabling processors to scale up in speed as workload demands increase.

These models highlight Supermicro's commitment to flexibility and expandability. Both the 5017C-MTF and 5017C-MTRF include multiple PCIe slots so users can integrate various expansion cards according to their requirements. Additionally, the dual Gigabit Ethernet ports enhance networking capabilities, supporting multiple connectivity options to meet organizational demands.

Storage is an important aspect of any server solution, and these models do not disappoint. They offer support for multiple SATA drives and come with options for SSD integration for high-speed data access. This makes the 5017C-MTF and 5017C-MTRF well-suited for virtualization, cloud storage solutions, or even as a database server.

The systems also boast a compact and energy-efficient design, making them ideal for space-constrained environments. The 1U rackmount form factor allows for easy deployment in data center settings, while also promoting efficient airflow and cooling design. Furthermore, both models meet stringent energy efficiency standards, which can lead to significant power savings over time.

Security and remote management features are also key highlights of the 5017C-MTF and 5017C-MTRF. Supermicro’s Intelligent Management Technology (IMT) software allows administrators to monitor system health remotely and perform management tasks effectively.

In summary, the Supermicro 5017C-MTF and 5017C-MTRF present robust server solutions packed with cutting-edge technology, flexible expansion options, and a focus on efficiency and security, catering to the evolving needs of modern businesses.