SUPER MICRO Computer 2042G-TRF Rack Mounting Considerations, Ambient Operating Temperature

Page 19

Chapter 2: Server Installation

Allow the hot plug SAS drives and power supply modules to cool before touch- ing them.

Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).

Reduced Airflow

Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).

2-3

Image 19
Contents Super Page About This Manual PrefaceManual Organization Advanced Chassis Setup Advanced Serverboard SetupBios Preface Table of Contents System Interface Advanced Chassis Setup Appendix C System Specifications Page Overview Chapter IntroductionSerial ATA Serverboard FeaturesProcessors Memory SAS AS-2042G-6RF OnlyGraphics Controller Other FeaturesEthernet Ports Onboard Controllers/PortsServer Chassis Features AMD SR5690/SP5100 Chipset System Block Diagram Asia-Pacific Contacting SupermicroHeadquarters EuropePreparing for Setup Chapter Server InstallationUnpacking the System Choosing a Setup Location Rack Mounting Considerations Ambient Operating TemperatureIdentifying the Sections of the Rack Rails Installing the System into a RackInstalling the Inner Rails Installing the Outer RailsInstalling the Server into a Rack Installing the Server into the RackAccessing the Inside of the System Checking the Serverboard SetupChecking the Components and Setup Checking the Airflow Preparing to Power OnProviding Power Checking the DrivesPage Control Panel Buttons ResetPower Chapter System InterfaceControl Panel LEDs Power FailOverheat/Fan Fail HDD SAS Drive Carrier LEDsPage Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard CR2032 Battery Operating PrecautionsPrecautions Chapter Advanced Serverboard SetupHandling the Serverboard Installing to the Chassis Serverboard InstallationUnpacking Connecting the Control Panel Connecting CablesConnecting Data Cables Connecting Power CablesRear I/O Ports I/O PortsInstallation Procedure Installing the Processor and HeatsinkInstalling the Processors Socket, which may damage SNK-0043P Heatsink Installing a Passive CPU HeatsinkMaximum Memory Installing MemoryInstalling Memory SupportChannel # Dimms CPUMax. MHz Max. GB 5V DIMMs 35V DIMMs Per Channel Dimm Populations OptionsPossible System Memory Allocation & Availability Dimm TypeAdding PCI Add-On Cards Installing an Add-on CardServerboard Details Jumper Description Default SettingH8QG6/i-F Quick Reference Connector Description Advanced Serverboard SetupPower Connectors Connector DefinitionsReset Connector Overheat OH/Fan Fail/PWR Fail/UID Power Fail LEDHDD/FP UID Switch Power LED ConnectorFan Headers Video ConnectorUniversal Serial Bus Ports USB HeadersSMBus Header Power I2CWake-On-LAN ATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/SpeakerChassis Intrusion Overheat LEDLAN1/2 Ethernet Ports Compact Flash Card PWR ConnectorUnit Identifier Button Trusted Platform Module HeaderJBT1 contact pads Jumper SettingsExplanation of Jumpers Cmos ClearSAS Enable/Disable Watch Dog Enable/DisableVGA Enable/Disable LAN1/2 Enable/DisableBMC Jumper Backpanel USB Wake-Up Enable JPUSB1 Jumper SettingsBMC Jumper Enable JPB1 Jumper Settings USB Wake-UpDedicated Ipmi LAN LEDs Onboard IndicatorsPower LED LAN1/LAN2 LEDsSata Ports Pin Definitions SAS and Sata Drive ConnectionsSata Ports SAS Ports H8QG6-F OnlyBuilding a Driver Diskette Installing the OS/SATA DriverEnabling Sata RAID Serial ATA SataBios Setup Screen Enabling Sata RAID in the BiosInstalling the RAID Driver During OS Installation Using the Adaptec RAID UtilityDriver/Tool Installation Display Screen Installing DriversSupero Doctor Page Page System Fans Control PanelPort Replacing System Fans System Fan FailureRemoving a fan Installing a new fan Drive Bay Installation/RemovalAccessing the Drive Bays SAS/SATA Drive InstallationInstalling/removing SAS/SATA drives Page SAS/SATA Drive Backplane DVD-ROM Drive InstallationSAS/SATA Backplane Connections Removing the power supply Power SupplyPower Supply Failure Removing/Replacing the Power SupplyRemoving a Power Supply Module Page Chapter Starting the Setup UtilityIntroduction Boot Features Advanced Settings MenuMain Menu  Processor & Clock Options NorthBridge Chipset Configuration Memory Configuration Advanced Chipset ControlDRAM Timing Configuration ECC ConfigurationPrimary/Secondary/Third IDE Master/Slave IDE/SATA ConfigurationBit Data Transfer DMA ModeIDE Detect Timeout Sec A.R.TSuperI/O Configuration  PCI/PNP ConfigurationRemote Access Configuration System Fan Monitor Hardware Health ConfigurationACPI Configuration IP Address IPMI ConfigurationView BMC System Event Log Set LAN ConfigurationSubnet Mask Security Settings MenuEvent Log Configuration MAC AddressBoot Settings Menu Network Drives Exit MenuAmibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description Page Installing Windows to a RAID System Appendix B Installing WindowsInstalling Windows to a Non-RAID System Appendix C System Specifications Serverboard WeightPower Supply Expansion SlotsRegulatory Compliance From front