Raypak B6000 manual TS Boiler Start Times Sec Boiler #1

Page 23

R

 

30070

40070

TS - Boiler Start Times (Sec) Boiler #1

 

R

 

30071

40071

TS - Boiler Start Times (Sec) Boiler #2

 

R

 

30072

40072

TS - Boiler Start Times (Sec) Boiler #3

 

R

 

30073

40073

TS - Boiler Start Times (Sec) Boiler #4

 

R

 

30074

40074

TS - Boiler Start Times (Sec) Boiler #5

 

R

 

30075

40075

TS - Boiler Start Times (Sec) Boiler #6

 

R

 

30076

40076

TS - Boiler Start Times (Sec) Boiler #7

 

R

 

30077

40077

TS - Boiler Start Times (Sec) Boiler #8

 

R

 

30078

40078

Time - Hrs

 

 

 

R

 

30079

40079

Time - Min

 

 

 

R

 

30080

40080

Time - DWK

 

 

 

R

 

30081

40081

Lead Change

 

 

 

R

 

30082

40082

Hrs Remaining

 

 

 

R

10833

30083

40083

Bit 0 = Setback on (1)

 

 

 

R

 

30084

40084

Boiler Valve Up Times (Sec)

#1

2 words per

R

 

30086

40086

Boiler Valve Up Times (Sec)

#2

2 words per

R

 

30088

40088

Boiler Valve Up Times (Sec)

#3

2 words per

R

 

30090

40090

Boiler Valve Up Times (Sec)

#4

2 words per

R

 

30092

40092

Boiler Valve Up Times (Sec)

#5

2 words per

R

 

30094

40094

Boiler Valve Up Times (Sec)

#6

2 words per

R

 

30096

40096

Boiler Valve Up Times (Sec)

#7

2 words per

R

 

30098

40098

Boiler Valve Up Times (Sec)

#8

2 words per

R

 

30100

40100

Boiler Valve Down Times (Sec)

#1

2 words per

R

 

30102

40102

Boiler Valve Down Times (Sec)

#2

2 words per

R

 

30104

40104

Boiler Valve Down Times (Sec)

#3

2 words per

R

 

30106

40106

Boiler Valve Down Times (Sec)

#4

2 words per

R

 

30108

40108

Boiler Valve Down Times (Sec)

#5

2 words per

R

 

30110

40110

Boiler Valve Down Times (Sec)

#6

2 words per

R

 

30112

40112

Boiler Valve Down Times (Sec)

#7

2 words per

R

 

30114

40114

Boiler Valve Down Times (Sec)

#8

2 words per

R

 

30116

40116

Spare

 

 

 

R

 

30117

40117

Spare

 

 

 

R

 

30118

40119

Spare

 

 

 

R

 

30119

40119

Spare

 

 

 

R

 

30120

40120

Spare

 

 

 

R

 

30121

40121

Spare

 

 

 

R

 

30122

40122

Spare

 

 

 

R

 

30123

40123

O/Cdb (Off T>=C, OnT<=OC - O/Cdb)

 

R

 

30124

40124

KPN : Proportional. Constant Numerator (0-255)

 

R

 

30125

40125

KPD : Proportional. Constant Denominator (0-255)

 

R

 

30126

40126

KDN : Differential. Constant Numerator (0-255)

 

R

 

30127

40127

KDD : Differential Constant Denominator (0-255)

 

R

 

30128

40128

Maximum Water Temp

 

 

 

R

 

30128

40129

Maximum Water Temp Fault

(0 = OK, 1 = Stpt > Max Temp,

 

 

 

 

 

2 = nite Stpt > Max Temp, 3 = Target > Max Temp)

R

 

30130

40130

Water Sensor

(0 = OK, 1 = Open, 2 = Shorted)

R

 

30131

40131

Outdoor Sensor

(0 = OK, 1 = Open, 2 = Shorted)

R

 

30132

40132

Spare

 

 

 

R/W

 

30133

40133

O/Cdb ( Off T > = C, On T< = OC - O/Cdb)

 

R/W

 

30134

40134

KPN : Proportional. Constant Numerator (0-255)

 

R/W

 

30135

40135

KPD : Proportional. Constant Denominator (0-255)

 

R/W

 

30136

40136

KDN : Differential. Constant Numerator (0-255)

 

R/W

 

30137

40137

KDD : Differential. Constant Denominator (0-255)

 

W

 

30138

40138

Maximum Water Temperature

 

 

A-5

23

Image 23
Contents Installation and Operating Manual Table of Contents Raypak B6000 System Protocol Interface Contents Quantity Installation and Mounting Wiring T-3 B6000 System Control Board Check Your Power Source Page 11.0.T-3 Product Specifications Modbus Communications Command TypesCommand Error Checking Modbus Register Map Data IntegritySW1 Modbus Port Configuration Dip Switch ConfigurationIndicates Factory Setting 11.3.2 B6000 Communications 11.3.1.3 T-3 Jumper ConfigurationsModbus Protocol Support Modbus CommandsFunction Address Slave Driver Code Command Range Comments Modbus Error CodesLED Indicators DiagnosticsTechnical Support ProSoft Support, Service and WarrantyService and Repair Limited Warranty Modbus Register Map Appendix aBoiler #1 Function Function Function Type DescriptionBit Boiler #5 Boiler #2Boiler #3 Boiler #4Boiler #8 Boiler #6Boiler #7 40070 TS Boiler Start Times Sec Boiler #1
Related manuals
Manual 51 pages 14.6 Kb

B6000 specifications

The Raypak B6000 is a high-efficiency boiler designed for residential and commercial heating applications. Known for its reliability and advanced features, the B6000 exemplifies Raypak's commitment to engineering excellence and innovative technology.

One of the standout attributes of the Raypak B6000 is its robust construction. The boiler is built with high-quality materials, ensuring durability and longevity in a variety of environments. It features a compact design, which allows for easy installation even in spaces with limited room. Moreover, it has a user-friendly interface that facilitates straightforward operation and maintenance, making it accessible for both homeowners and HVAC professionals.

The B6000 is equipped with advanced heating technologies that enhance its performance and efficiency. It utilizes a modulating burner system that adjusts the heat output based on the demand, ensuring optimal energy usage. This not only leads to lower energy bills but also contributes to a reduced carbon footprint, making the B6000 an environmentally friendly choice.

Another key feature of the Raypak B6000 is its stainless steel heat exchanger, which provides superior heat transfer and contributes to the boiler's overall efficiency. The heat exchanger is designed to withstand high temperatures and pressures, ensuring safety and reliability throughout its operation. Additionally, the B6000 offers multiple venting options, including direct venting and horizontal venting, providing flexibility in installation.

The B6000 also comes with integrated controls that allow users to easily monitor and adjust settings. These controls can enhance energy efficiency by accommodating varying heating needs throughout the day. Furthermore, the boiler is compatible with smart home systems, enabling remote operation and monitoring.

In terms of safety features, the Raypak B6000 is equipped with multiple safety sensors and shutoff systems to ensure safe operation. This includes automatic shutdown in case of malfunction, preventing potential hazards.

Overall, the Raypak B6000 is a top-tier boiler that combines efficiency, reliability, and advanced technology, making it a preferred choice for those seeking a dependable heating solution. It is suitable for various applications, from residential heating to larger commercial projects, further establishing its versatility in the market. Whether for new installations or replacements, the B6000 stands out as a reliable option for efficient heating solutions.