Raypak manual Raypak B6000 System Protocol Interface Contents Quantity

Page 3

T-3 (Raypak B6000 System Protocol Interface)

Contents

Quantity

COMPACT DISC (CD)

1

T-3

1

EPROM (CPX.XNMn) in small black ESD box

1

Check packaging for damage or missing components.

IMPORTANT NOTICE: These instructions are intended for the use by qualified personnel only, specifically trained and experienced in the installation of this type of equipment and related sys- tem components. Installation and service personnel may be required by some states to be licensed. If your state is such, be sure your contractor bears the appropriate license. Only quali- fied persons shall attempt to repair this equipment. Repair must be according to these instruc- tions.

WARNING: Improper installation, adjustment, alteration, service or maintenance may damage the equipment, create a hazard resulting in asphyxiation, explosion, fire, electric shock, personal injury or property damage and will void the warranty.

CAUTION: ONE SUPPLY SOURCE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL CONNECTIONS BEFORE SERVICING.

CAUTION: RISK OF ELECTRIC SHOCK, DISCONNECT SWITCH IS REQUIRED TO DE- ENERGIZE THE EQUIPMENT BEFORE SERVICING.

NOTE: Minimum 18 AWG, 105°C, stranded wire must be used for all low voltage (less than 30 volts) external connections to the unit. Solid conductors should not be used because they can cause excessive tension on contact points. Install conduit as appropriate. All high voltage wires must be the same size (105°C, stranded wire) as the ones on the unit or larger.

Thank you for selecting the Raypak B6000 Boiler Management System and the Raypak Communication Interface. It is our sincere hope that you will enjoy its power, ease of use and energy saving features.

Please follow the instructions carefully to insure proper installation.

FORWARD

The Raypak Communication Interface is designed to allow the Communication Interface System to monitor and control the Raypak B6000 Boiler Management System.

3

Image 3
Contents Installation and Operating Manual Table of Contents Raypak B6000 System Protocol Interface Contents Quantity Installation and Mounting Wiring T-3 B6000 System Control Board Check Your Power Source Page 11.0.T-3 Product Specifications Command Types Command Error CheckingModbus Communications Modbus Register Map Data IntegritySW1 Modbus Port Configuration Dip Switch ConfigurationIndicates Factory Setting 11.3.2 B6000 Communications 11.3.1.3 T-3 Jumper ConfigurationsModbus Protocol Support Modbus CommandsFunction Address Slave Driver Code Command Range Comments Modbus Error CodesLED Indicators DiagnosticsProSoft Support, Service and Warranty Service and RepairTechnical Support Limited Warranty Modbus Register Map Appendix aFunction Function Function Type Description BitBoiler #1 Boiler #5 Boiler #2Boiler #3 Boiler #4Boiler #6 Boiler #7Boiler #8 40070 TS Boiler Start Times Sec Boiler #1
Related manuals
Manual 51 pages 14.6 Kb

B6000 specifications

The Raypak B6000 is a high-efficiency boiler designed for residential and commercial heating applications. Known for its reliability and advanced features, the B6000 exemplifies Raypak's commitment to engineering excellence and innovative technology.

One of the standout attributes of the Raypak B6000 is its robust construction. The boiler is built with high-quality materials, ensuring durability and longevity in a variety of environments. It features a compact design, which allows for easy installation even in spaces with limited room. Moreover, it has a user-friendly interface that facilitates straightforward operation and maintenance, making it accessible for both homeowners and HVAC professionals.

The B6000 is equipped with advanced heating technologies that enhance its performance and efficiency. It utilizes a modulating burner system that adjusts the heat output based on the demand, ensuring optimal energy usage. This not only leads to lower energy bills but also contributes to a reduced carbon footprint, making the B6000 an environmentally friendly choice.

Another key feature of the Raypak B6000 is its stainless steel heat exchanger, which provides superior heat transfer and contributes to the boiler's overall efficiency. The heat exchanger is designed to withstand high temperatures and pressures, ensuring safety and reliability throughout its operation. Additionally, the B6000 offers multiple venting options, including direct venting and horizontal venting, providing flexibility in installation.

The B6000 also comes with integrated controls that allow users to easily monitor and adjust settings. These controls can enhance energy efficiency by accommodating varying heating needs throughout the day. Furthermore, the boiler is compatible with smart home systems, enabling remote operation and monitoring.

In terms of safety features, the Raypak B6000 is equipped with multiple safety sensors and shutoff systems to ensure safe operation. This includes automatic shutdown in case of malfunction, preventing potential hazards.

Overall, the Raypak B6000 is a top-tier boiler that combines efficiency, reliability, and advanced technology, making it a preferred choice for those seeking a dependable heating solution. It is suitable for various applications, from residential heating to larger commercial projects, further establishing its versatility in the market. Whether for new installations or replacements, the B6000 stands out as a reliable option for efficient heating solutions.