SMC Networks SMCGS24 manual Industry Canada Class a, Japan Vcci Class a

Page 8

COMPLIANCES

• Electrostatic Discharge according to EN 61000-4-2:1995

 

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC

 

 

power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency fields:

 

 

EN 61000-4-6:1996 (0.15 - 80 MHz with

 

 

1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

 

EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

EN 60950-1:2001

Industry Canada - Class A

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques,” NMB-003 édictée par le ministère des Communications.

Japan VCCI Class A

iv

Image 8 Contents
Page Page EZ Switch 10/100/1000 User Guide Trademarks Limited Warranty Limited Warranty EC Conformance Declaration Class a CompliancesFCC Class a Industry Canada Class a Japan Vcci Class aCompliances Power Cord Set Vii Viii Halten Audience Environmental StatementPurpose Safety Compliance Warnhinweis Faseroptikanschlüsse Optische SicherheitXii Table of Contents Viii Features and Benefits IntroductionFront Panel RJ-45 Ports Front Panel LEDsRear Panel Selecting a Site Installing the SwitchPackage Contents Instructions Installing the Switch Application Example Typical application for the SMCGS16 is illustrated belowTroubleshooting Diagnosing Switch IndicatorsSymptom Possible Solutions10BASE-T/100BASE-TX Pin Assignments Cable SpecificationsCables Pin MDI-X Signal Name MDI Signal Name 1000BASE-T Pin Assignments1000BASE-T Cable Requirements Cable Testing for Existing Category 5 CableAdjusting Existing Category 5 Cabling Product Specifications EZ Switch 10/100/1000Weight Power ConsumptionPower Requirement TemperatureProduct Specifications Page For Technical SUPPORT, Call
Related manuals
Manual 34 pages 13.34 Kb