INSTRUCTIONS

There should be adequate space (approximately two inches) on all sides for proper air flow.

Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference such as radios, transmitters, etc.

Make sure that a properly grounded power outlet is within 2.44 meters (8 feet) of the switch and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended.

Instructions

1.Positioning the Switch: For desktop or shelf mounting, attach the four adhesive foot pads to the bottom of the switch. For rack mounting, install into a standard EIA 19-inch rack using the included brackets.

2.Applying Power: Plug one end of the power adapter into the socket on the switch’s rear panel, and the other end into an appropriate electrical outlet. Check the Power LED to be sure power is on.

Note: It is not necessary to power off the switch before connecting or disconnecting any UTP cables, as these actions will not disrupt the operation of other devices attached to the switch.

3.Connecting PCs: Connect each PC to an RJ-45 port on the switch using Category 5 or 5e shielded or unshielded twisted-pair (UTP or STP) cable, maximum length 100 meters (328 ft). The EZ Switch 10/ 100/1000 will support up to 16 PCs. All ports on the switch support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.

5

Image 23 Contents
Page Page EZ Switch 10/100/1000 User Guide Trademarks Limited Warranty Limited Warranty EC Conformance Declaration Class a CompliancesFCC Class a Japan Vcci Class a Industry Canada Class aCompliances Power Cord Set Vii Viii Halten Audience Environmental StatementPurpose Warnhinweis Faseroptikanschlüsse Optische Sicherheit Safety ComplianceXii Table of Contents Viii Introduction Features and BenefitsFront Panel LEDs Front Panel RJ-45 PortsRear Panel Selecting a Site Installing the SwitchPackage Contents Instructions Installing the Switch Typical application for the SMCGS16 is illustrated below Application ExamplePossible Solutions TroubleshootingDiagnosing Switch Indicators Symptom10BASE-T/100BASE-TX Pin Assignments Cable SpecificationsCables 1000BASE-T Pin Assignments Pin MDI-X Signal Name MDI Signal Name1000BASE-T Cable Requirements Cable Testing for Existing Category 5 CableAdjusting Existing Category 5 Cabling EZ Switch 10/100/1000 Product SpecificationsTemperature WeightPower Consumption Power RequirementProduct Specifications Page For Technical SUPPORT, Call