TROUBLESHOOTING

TROUBLESHOOTING

Diagnosing Switch Indicators

1.Symptom

Power LED does not light after power on.

Probable Causes

• AC power cord may be defective.

Possible Solutions

Check for loose connections.

Check the power outlet by using it for another device.

Replace the AC power cord.

2.Symptom

Link LED does not light after connection is made.

Probable Causes

Switch port, network card or cable may be defective.

Possible Solutions

Check that the switch and attached device are both powered on.

Be sure the network cable is connected to both devices.

Verify that Category 5 or better cable is used for 10/100 Mbps connections, Category 5 or 5e cable for 1000 Mbps connections, and that the length of any cable does not exceed 100 meters (328 feet).

Check the network card and cable connections for defects.

Replace the defective card or cable if necessary.

8

Image 26 Contents
Page Page EZ Switch 10/100/1000 User Guide Trademarks Limited Warranty Limited Warranty EC Conformance Declaration Class a CompliancesFCC Class a Industry Canada Class a Japan Vcci Class aCompliances Power Cord Set Vii Viii Halten Audience Environmental StatementPurpose Safety Compliance Warnhinweis Faseroptikanschlüsse Optische SicherheitXii Table of Contents Viii Features and Benefits IntroductionFront Panel RJ-45 Ports Front Panel LEDsRear Panel Selecting a Site Installing the SwitchPackage Contents Instructions Installing the Switch Application Example Typical application for the SMCGS16 is illustrated belowSymptom TroubleshootingDiagnosing Switch Indicators Possible Solutions10BASE-T/100BASE-TX Pin Assignments Cable SpecificationsCables Pin MDI-X Signal Name MDI Signal Name 1000BASE-T Pin Assignments1000BASE-T Cable Requirements Cable Testing for Existing Category 5 CableAdjusting Existing Category 5 Cabling Product Specifications EZ Switch 10/100/1000Power Requirement WeightPower Consumption TemperatureProduct Specifications Page For Technical SUPPORT, Call