9.1VOLUME FLOW CONVERSION CHART

Convert known units to cubic feet per second (CFPS) or gallons per minute (GPM) for use with Chart A.2

TO CONVERT FROM

TO

MULTIPLY BY

Gallons Per Minute (GPM)

Cubic Feet Per

2.228

E-03

 

Per Second (CFPS)

 

 

Gallons Per Day (GPD)

CFPS

1.547

E-06

Barrels Per Day (BPD)

CFPS

6.531

E-5

Cubic Ft. Per Minute (CFPM)

CFPS

1.667

E-02

Cubic In. Per Minute (CIPM)

CFPS

9.645

E-06

Milliliters Per Minute (MLPM)

CFPS

5.886

E-07

Milliliters Per Second (MLPS)

CFPS

3.531

E-05

Milliliters Per Hour (MLPH)

CPFS

9.810

E-09

Liters Per Day (LPD)

CPFS

4.087

E-07

Gallons Per Day (GPD)

GPM

6.944

E-04

Barrels Per Day (BPD)

GPM

2.931

E-02

Cubic Ft. Per Second (CFPS)

GPM

4.488

E+02

Cubic Ft. Per Minute (CFPM)

GPM

7.481

 

Cubic In. Per Minute (CIPM)

GPM

4.329

E-03

Milliliters Per Minute (MLPM)

GPM

2.642

E-04

Milliliters Per Second (MLPS)

GPM

4.403

E-06

Milliliters Per Hour (MLPH)

GPM

1.585

E-02

Liters Per Day (LPD)

GPM

1.835

E-04

IM-215 Rev-A.1

Series Innova-Switch™

Page 35 of 42

Image 35 Contents
INNOVA-SWITCH Series Before Starting Special Notice This manual covers the following model numbersTable of Contents Introduction Description Description IntroductionIM-215 Rev-A.1 Series Innova-Switch IM-215 Rev-A.1 Series Innova-Switch Thermal Differential Theory of Operation Level SwitchingFlow Switching Gas Or Liquid Flow Innova-Switch Model FS4200 Flow Response for Three Media IM-215 Rev-A.1 Series Innova-Switch Innova-Switch Models with the CE Option Switch Block Diagram Innova-Switch Switch Assembly Pipe or Vessel USE a 1 1/8 Inch 28.575mm OPEN-END InstallationWhen Installing Your Sierra Instruments Switch Into IM-215 Rev-A.1 Series Innova-Switch Innova-SwitchSWITCH Local Electronics Field Wiring Diagram Electrical InstallationIM-215 Rev-A.1 Series Innova-Switch Wiring Innova Switch Flow Switch Remote Electronics Option FieldRemote Electronics Cable Termination ConnectionsInnova-SwitchSWITCH Remote Electronics Field Wiring Diagram L.E.D. and Relay Status Logic Fail-safe Innova-Switch Electronics For Optimum OPERATION, Calibration Must be Accomplished Pre-Operational Check RED Green Relay Contact Sensor Status LED Innova-Switch Electronics Calibration Level IM-215 Rev-A.1 Series Innova-Switch IM-215 Rev-A.1 Series Innova-Switch Troubleshooting Intenance and Trouble ShootingCleaning Special Notice Process Connections Specifications TypeOperating Temperature Input PowerService Warranty and ServiceWarranty Connector Plates To Convert from Multiply by Volume Flow Conversion ChartFlow Conversion Chart Flow of Water Through Schedule 40 Steel Pipe Options Livetap LT Variable Insertion Thermocouple Output to and 10.4 RTD Output RT IM-215 Rev-A.1 Series Innova-Switch