Seagate ST9600205FC manual Invoking DST, Short and extended tests, Short test Function Code 001b

Page 25

A Drive Not Ready condition is reported by the drive under the following conditions:

Motor will not spin

Motor will not lock to speed

Servo will not lock on track

Drive cannot read configuration tables from the disk

In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.

6.2.6.2.2Invoking DST

To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.

6.2.6.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

6.2.6.2.4Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param- eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:

1.The Function Code field is set to the same value as sent in the DST command

2.The Self-Test Results Value field is set to Fh

3.The drive will store the log page to non-volatile memory

After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self- Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.

Savvio 10K.5 FC Product Manual, Rev. D

19

Image 25
Contents ST9900805FC ST9600205FC ST9450405FC ST9300605FC Savvio 10K.5 FCRevision history Contents Installation Savvio 10K.5 FC Product Manual, Rev. D Iii Savvio 10K.5 FC Product Manual, Rev. D Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS Directive Reference documentsGeneral description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacity Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time Prefetch/multi-segmented cache controlCache operation Prefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact Determining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyStorage PowerChoiceTM power management Physical/electrical specificationsPowerChoice modes AC power requirements DC power requirements for ST9900805FC model 2Gb 4Gb Amps DC power requirementsDC power requirements for ST9600205FC model 2Gb 4Gb Amps DC power requirements for ST9450405FC model 2Gb 4Gb Amps DC power requirements for ST9300605FC model 2Gb 4Gb Amps Power sequencing General DC power requirement notesConducted noise immunity Current profiles Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D ST9900805FC Power dissipationST9600205FC ST9450405FC ST9300605FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Vibration a. Operating-normal Air cleanlinessAcoustics Corrosive environment Mounting configuration dimensions Mechanical specificationsDrive internal defects/errors Defect and error managementDrive error recovery procedures FC-AL system errors Media Pre-Scan Background Media ScanDeferred Auto-Reallocation Idle Read After Write Setting and determining the current Type LevelProtection Information PI Levels of PIIdentifying a Protection Information drive Drive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Savvio 10K.5 FC Product Manual, Rev. D Temperature page 0Dh Inquiry data Mode Sense dataSavvio 10K.5 FC inquiry data Bytes Data hex Page Mode Data Header 00 00 00 00 45 dd 2f b0 00 00 00 00 00 00 02 00 00 00 00 34 65 f8 70 00 00 00 00 00 00 02 00 00 00 00 22 ec b2 5c 00 00 00 00 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 10.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID 10.6.1 TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Savvio 10K.5 FC Product Manual, Rev. D Index Devctrlcode Flogi Plogi Page Page Page Savvio 10K.5 FC Product Manual, Rev. D