Seagate ST9600205FC Fibre Channel fabric accept login, Fabric Login Accept ACC payload Bytes

Page 61

10.1.9Fibre Channel fabric accept login

Table 15 lists the required content of the Fabric Login Accept (ACC) payload from the fabric.

Table 15: Fabric Login Accept (ACC) payload

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

02

00

00

00

09

09

BB

BB

CF

XX

FS

FS

R_

A_

T0

V_

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

E_

D_

T0

V_

PN

PN

PN

PN

PN

PN

PN

PN

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-35

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36-47

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48-51

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-63

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-67

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-79

 

 

 

 

SO

SO

xx

xx

XX

XX

FS

FS

XX

xx

XX

XX

Class 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-83

OS

OS

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-95

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96-99

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-111

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Vendor -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-115

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XIndicates a four-bit (hex) field is not checked.

x Indicates a single bit is not checked.

BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).

CF

Common features. This binary field selects the common features requested by the fabric login.

 

MSB

Continuously increasing offset

x

 

 

Random relative offset

x

 

 

Valid version level

x

 

 

N_Port/F_Port

Must = 1, F_Port

 

 

Alternate credit model

Must = 1

 

 

Other bits reserved

xxx XX

FS

Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a

 

multiple of four bytes. The receive buffer field size in the Class 3 parameters is used. The drive uses the lower FS of Fabric Login

 

Accept or N_Port Login when sending frames to an initiator.

PN

Port Name. The fabric port name is saved with the login parameters. If a change of the port name is detected during a FAN, an

 

implicit logout occurs and a LS_RJT is returned to the fabric.

NN

Node Name. The drive does not check or save the node name.

SO

Service Options—Class 3 only.

 

 

MSB

Class valid

Must = 1

 

 

Intermix

x

 

 

Stacked connection req.

xx

 

 

Sequential delivery

Must = 1

 

 

Other bits reserved

xxx XX

Savvio 10K.5 FC Product Manual, Rev. D

55

Image 61
Contents ST9900805FC ST9600205FC ST9450405FC ST9300605FC Savvio 10K.5 FCRevision history Contents Installation Savvio 10K.5 FC Product Manual, Rev. D Iii Savvio 10K.5 FC Product Manual, Rev. D Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS Directive Reference documentsGeneral description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacity Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time Prefetch/multi-segmented cache controlCache operation Prefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact Determining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyStorage PowerChoiceTM power management Physical/electrical specificationsPowerChoice modes AC power requirements DC power requirements for ST9900805FC model 2Gb 4Gb Amps DC power requirementsDC power requirements for ST9600205FC model 2Gb 4Gb Amps DC power requirements for ST9450405FC model 2Gb 4Gb Amps DC power requirements for ST9300605FC model 2Gb 4Gb Amps Power sequencing General DC power requirement notesConducted noise immunity Current profiles Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D ST9900805FC Power dissipationST9600205FC ST9450405FC ST9300605FC Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Vibration a. Operating-normal Air cleanlinessAcoustics Corrosive environment Mounting configuration dimensions Mechanical specificationsDrive internal defects/errors Defect and error managementDrive error recovery procedures FC-AL system errors Media Pre-Scan Background Media ScanDeferred Auto-Reallocation Idle Read After Write Setting and determining the current Type LevelProtection Information PI Levels of PIIdentifying a Protection Information drive Drive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Savvio 10K.5 FC Product Manual, Rev. D Temperature page 0Dh Inquiry data Mode Sense dataSavvio 10K.5 FC inquiry data Bytes Data hex Page Mode Data Header 00 00 00 00 45 dd 2f b0 00 00 00 00 00 00 02 00 00 00 00 34 65 f8 70 00 00 00 00 00 00 02 00 00 00 00 22 ec b2 5c 00 00 00 00 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 10.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID 10.6.1 TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Savvio 10K.5 FC Product Manual, Rev. D Index Devctrlcode Flogi Plogi Page Page Page Savvio 10K.5 FC Product Manual, Rev. D