Seagate ST9900805FC, ST9600205FC manual Drive Self Test DST, DST failure definition, Implementation

Page 24

be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 1: Temperature Log Page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

6.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short test

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

6.2.6.1DST failure definition

The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

6.2.6.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

6.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

18

Savvio 10K.5 FC Product Manual, Rev. D

Image 24
Contents Savvio 10K.5 FC ST9900805FC ST9600205FC ST9450405FC ST9300605FCRevision history Contents Installation Savvio 10K.5 FC Product Manual, Rev. D Iii Savvio 10K.5 FC Product Manual, Rev. D Seagate Technology support services Seagate Online Support and ServicesScope Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents China Restriction of Hazardous Substances RoHS DirectiveGeneral description Standard features Media descriptionPerformance ReliabilityFormatted capacities Factory-installed options Programmable drive capacityPerformance characteristics Internal drive characteristicsAccess time Seek performanceFormat command execution time minutes General performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact Reporting control Determining ratePredictive failures Thermal monitorState of the drive prior to testing Temperature Log Page 0DhDrive Self Test DST DST failure definitionInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortStorage Physical/electrical specifications PowerChoiceTM power managementPowerChoice modes AC power requirements DC power requirements DC power requirements for ST9900805FC model 2Gb 4Gb AmpsDC power requirements for ST9600205FC model 2Gb 4Gb Amps DC power requirements for ST9450405FC model 2Gb 4Gb Amps DC power requirements for ST9300605FC model 2Gb 4Gb Amps General DC power requirement notes Power sequencingConducted noise immunity Current profiles Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Power dissipation ST9900805FCST9600205FC ST9450405FC ST9300605FC Temperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. Operating Shock and vibrationShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environment Mechanical specifications Mounting configuration dimensionsDefect and error management Drive internal defects/errorsDrive error recovery procedures FC-AL system errors Background Media Scan Media Pre-ScanDeferred Auto-Reallocation Setting and determining the current Type Level Idle Read After WriteProtection Information PI Levels of PIIdentifying a Protection Information drive Installation Drive ID/option selectionDrive orientation CoolingDrive mounting Air flowGrounding FC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Savvio 10K.5 FC Product Manual, Rev. D Temperature page 0Dh Mode Sense data Inquiry dataSavvio 10K.5 FC inquiry data Bytes Data hex Page Mode Data Header 00 00 00 00 45 dd 2f b0 00 00 00 00 00 00 02 00 00 00 00 34 65 f8 70 00 00 00 00 00 00 02 00 00 00 00 22 ec b2 5c 00 00 00 00 00 00 02 Miscellaneous operating features and conditions Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type FC-AL transmitters and receiversPower Fault LED OutEnable port bypass signals Active LED OutMotor start controls Parallel Enclosure Services Interface ESI 10.5.11 SEL6 through SEL0 ID linesAlpa SEL ID Signal characteristics 10.6.1 TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Savvio 10K.5 FC Product Manual, Rev. D Index Devctrlcode Flogi Plogi Page Page Page Savvio 10K.5 FC Product Manual, Rev. D