Seagate ST9300605FC Reporting control, Determining rate, Predictive failures, Thermal monitor

Page 23

Reporting control

Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to the reporting method. For example, if the MRIE is set to one, the firmware will issue to the host an 01-5D00 sense code. The FRU field contains the type of predictive failure that occurred. The error code is preserved through bus resets and power cycles.

Determining rate

S.M.A.R.T. monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors increases to an unacceptable level. To determine rate, error events are logged and compared to the number of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.

S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.

Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the inter- val and failure counters are reset and the process starts over.

Predictive failures

S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firm- ware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accom- plish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the pre- dictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter. There is a separate Failure History Counter for each attribute.

6.2.5Thermal monitor

Savvio 10K.5 FC drives implement a temperature warning system which:

1.Signals the host if the temperature exceeds a value which would threaten the drive.

2.Signals the host if the temperature exceeds a user-specified value.

3.Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.

A temperature sensor monitors the drive temperature and issues a warning over the interface when the tem- perature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.

The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci- fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the user-specified temperature.

This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).

The current algorithm implements two temperature trip points. The first trip point is set at 68°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using the Log Select command. The reference temperature parameter in the temperature log page (see Table 1) can

Savvio 10K.5 FC Product Manual, Rev. D

17

Image 23
Contents ST9900805FC ST9600205FC ST9450405FC ST9300605FC Savvio 10K.5 FCRevision history Contents Installation Savvio 10K.5 FC Product Manual, Rev. D Iii Savvio 10K.5 FC Product Manual, Rev. D Seagate Online Support and Services Seagate Technology support servicesScope Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS Directive Reference documentsGeneral description Media description Standard featuresFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsSeek performance Performance characteristicsInternal drive characteristics Access timePrefetch/multi-segmented cache control Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsPerformance impact 4 S.M.A.R.TControlling S.M.A.R.T Thermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingTemperature Log Page 0Dh Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bStorage Product warrantyAbort PowerChoice modes Physical/electrical specificationsPowerChoiceTM power management AC power requirements DC power requirements for ST9900805FC model 2Gb 4Gb Amps DC power requirementsDC power requirements for ST9600205FC model 2Gb 4Gb Amps DC power requirements for ST9450405FC model 2Gb 4Gb Amps DC power requirements for ST9300605FC model 2Gb 4Gb Amps Conducted noise immunity General DC power requirement notesPower sequencing Current profiles Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D ST9900805FC Power dissipationST9600205FC ST9450405FC ST9300605FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Recommended mounting Acoustics Air cleanlinessVibration a. Operating-normal Corrosive environment Mounting configuration dimensions Mechanical specificationsDrive error recovery procedures Defect and error managementDrive internal defects/errors FC-AL system errors Deferred Auto-Reallocation Background Media ScanMedia Pre-Scan Levels of PI Setting and determining the current Type LevelIdle Read After Write Protection Information PIIdentifying a Protection Information drive Cooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Savvio 10K.5 FC Product Manual, Rev. D Temperature page 0Dh Savvio 10K.5 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header 00 00 00 00 45 dd 2f b0 00 00 00 00 00 00 02 00 00 00 00 34 65 f8 70 00 00 00 00 00 00 02 00 00 00 00 22 ec b2 5c 00 00 00 00 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 10.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Device control codes Signal characteristics10.6.1 TTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Savvio 10K.5 FC Product Manual, Rev. D Index Devctrlcode Flogi Plogi Page Page Page Savvio 10K.5 FC Product Manual, Rev. D