Seagate ST9600205FC manual Installation, Drive ID/option selection, Drive orientation, Cooling

Page 53

9.0Installation

Savvio 10K.5 FC disk drive installation is a plug-and-play process. There are no jumpers, switches, or termina- tors on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC-SCA) no cables are required. See Section 10.5 for additional information about this connector.

Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.

If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL IDs) on the backpanel so that no two devices have the same selection ID. This is called the hard assigned arbi- trated loop physical address (AL_PA). There are 125 AL_PAs available (see Table 28). If you set the AL_PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec- tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto- matically.

Loop initialization is the process used to verify or obtain an address. The loop initialization process is per- formed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.

Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.

It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the drive only if you want to select a different logical block size.

9.1Drive ID/option selection

All drive options are made through the interface connector (J1). Table 25 provides the pin descriptions for the 40-pin Fibre Channel single connector (J1).

9.2Drive orientation

The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (disks level) and vertical (drive on its side) orientations, which are the two pre- ferred mounting orientations.

9.3Cooling

The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 7.5.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 7.5.1.

Savvio 10K.5 FC Product Manual, Rev. D

47

Image 53
Contents ST9900805FC ST9600205FC ST9450405FC ST9300605FC Savvio 10K.5 FCRevision history Contents Installation Savvio 10K.5 FC Product Manual, Rev. D Iii Savvio 10K.5 FC Product Manual, Rev. D Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS Directive Reference documentsGeneral description Media description Standard featuresFormatted capacities PerformanceReliability Programmable drive capacity Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time Prefetch/multi-segmented cache controlCache operation Prefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T Determining rate Reporting controlPredictive failures Thermal monitorTemperature Log Page 0Dh State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bStorage Product warrantyAbort PowerChoice modes Physical/electrical specificationsPowerChoiceTM power management AC power requirements DC power requirements for ST9900805FC model 2Gb 4Gb Amps DC power requirementsDC power requirements for ST9600205FC model 2Gb 4Gb Amps DC power requirements for ST9450405FC model 2Gb 4Gb Amps DC power requirements for ST9300605FC model 2Gb 4Gb Amps Conducted noise immunity General DC power requirement notesPower sequencing Current profiles Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D Savvio 10K.5 FC Product Manual, Rev. D ST9900805FC Power dissipationST9600205FC ST9450405FC ST9300605FC Relative humidity Temperature a. OperatingEnvironmental limits Shock Effective altitude sea level a. OperatingShock and vibration Recommended mounting Acoustics Air cleanlinessVibration a. Operating-normal Corrosive environment Mounting configuration dimensions Mechanical specificationsDrive error recovery procedures Defect and error managementDrive internal defects/errors FC-AL system errors Deferred Auto-Reallocation Background Media Scan Media Pre-Scan Idle Read After Write Setting and determining the current Type LevelProtection Information PI Levels of PIIdentifying a Protection Information drive Drive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Savvio 10K.5 FC Product Manual, Rev. D Temperature page 0Dh Savvio 10K.5 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header 00 00 00 00 45 dd 2f b0 00 00 00 00 00 00 02 00 00 00 00 34 65 f8 70 00 00 00 00 00 00 02 00 00 00 00 22 ec b2 5c 00 00 00 00 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typeFault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 10.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIAlpa SEL ID Device control codes Signal characteristics10.6.1 TTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Savvio 10K.5 FC Product Manual, Rev. D Index Devctrlcode Flogi Plogi Page Page Page Savvio 10K.5 FC Product Manual, Rev. D