Specifications

 

 

 

 

 

 

 

 

 

 

 

Table 7

UPS specifications (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model #

 

 

 

 

 

 

Liebert® GXT35000RT230U

 

Agency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety

IEC62040-1:2008 version; UL 1778, c-UL Listed

 

 

 

 

 

EMI/EMC

IEC/EN/AS 62040-2 2nd Ed (Cat 2 – Table 6); FCC Class A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESD

 

EN61000-4-2, Level 4, Criteria A

 

 

 

 

 

 

 

 

 

 

 

 

Radiated Susceptibility

 

EN61000-4-3, Level 3, Criteria A

 

 

Electrical Fast Transient

 

EN61000-4-4, Level 4, Criteria A

 

 

 

 

 

 

 

 

 

 

 

 

Surge Immunity

 

EN61000-4-5, Level 3, Criteria A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transportation

 

 

ISTA Procedure 1A

 

Table 8

Operating temperature parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient Temperature, °C (°F)

 

 

pf @30°C ±3°C

 

pf @40°C ±3°C

 

 

 

 

(pf @ 86°F ±5.4°F)

 

(pf @ 104°F ±5.4°F)

 

 

 

 

 

 

 

 

 

5000RT230U

 

 

 

 

0.8pf

 

0.8pf

 

 

 

 

 

 

 

 

 

 

 

 

Table 9

Power distribution specifications

 

 

 

 

 

 

 

 

 

 

 

 

Model Number

 

 

 

 

PD2-CE5HDWRMBSU

 

 

PD2-Amp Rating

 

 

 

 

 

32 Amps

 

 

 

 

 

 

 

 

 

Input Power Connection

 

 

 

3-Wire Hard-Wired, 6-10mm2(8-10AWG)

 

 

Output Power Connection

 

 

 

3-Wire Hard-Wired, 6-10mm2(8-10AWG)

 

 

Input Branch Circuit Breaker Supplied by User

 

 

 

32A

 

 

 

 

 

 

 

 

 

Table 10 External battery cabinet specifications

 

 

 

 

 

 

 

 

 

 

 

Model Number

 

 

 

Liebert® GXT3-240VBATTCE

 

 

Used with UPS Model

 

 

 

 

Liebert GXT3 5000RT230U

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions, W x D x H, mm (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit (with bezel)

 

 

 

570 x 430 x 148 (22.4 x 16.9 x 5.8)

 

 

 

 

 

 

 

 

 

 

 

Shipping

 

 

 

745 x 530 x 407 (29.3 x 20.8 x 16)

 

 

 

 

 

 

 

 

 

 

 

 

Weight, kg (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

50.4 (111)

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

 

 

 

 

54 (119)

 

 

 

 

 

 

 

 

 

 

 

 

Battery Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

Valve-regulated, non-spillable, lead acid

 

 

 

 

 

 

 

 

 

 

 

 

Quantity x V

 

 

 

 

1 x 20 x 12V

 

 

 

 

 

 

 

 

 

 

Battery Manufacturer, Part #

 

 

5AH battery - CSB HR1221W or YUASA NPH5-12

 

 

 

 

 

 

 

 

 

 

 

 

Backup Time

 

 

 

 

See Table 11

 

 

 

 

 

 

 

 

 

 

 

 

Environmental

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Temp, °C (°F)

 

 

 

 

0 to 40 (32 to 104)

 

 

 

 

 

see Table 8 - Operating temperature parameters

 

 

 

 

 

 

 

 

 

Storage Temp , °C (°F)

 

 

 

 

-15 to 50 (5 to 122)

 

 

 

 

 

 

 

 

 

 

 

 

Relative Humidity

 

 

 

 

0-95% non-condensing

 

 

 

 

 

 

 

 

 

 

Operating Elevation

 

 

Up to 1000m (3280.83 ft.) at 25°C (77°F)

 

 

 

 

 

 

 

 

 

 

 

 

Agency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety

 

 

 

 

IEC62040-1:2008 version

 

 

 

 

 

 

 

 

 

 

 

 

Transportation

 

 

 

 

ISTA Procedure 1A

 

 

 

 

 

 

 

 

 

 

 

 