Specifications

12.0SPECIFICATIONS

Table 7

UPS specifications

 

 

 

 

 

Model #

Liebert® GXT35000RT230U

Rating

 

5000VA/4000W

Dimensions, mm (in)

 

 

Unit, W x D x H

570 x 430 x 220 (22.4 x 16.9 x 8.7)

 

 

 

 

Shipping, W x D x H

745 x 530 x 516 (29.3 x 20.9 x 20.3)

 

 

Weight, kg (lb)

 

 

Unit

60 (132.2)

 

 

 

 

Shipping

71 (156.5)

 

 

Input AC Parameters

 

 

Operating Frequency, Nom

50 or 60Hz (Factory Default = 50)

 

 

 

 

Factory Default VAC

230VAC

 

 

 

 

User-Configurable VAC

220/230/240VAC

 

(May be modified using included configuration program)

 

 

Operating Voltage Range Without Battery Operation

176 - 280VAC

 

 

 

 

Maximum Allowable VAC

280VAC

 

 

 

 

Input Frequency Without Battery Operation

40 - 70Hz

 

 

 

 

Input Power Connection

Hardwire Terminal Block Standard

 

(See 3.3 - Removable Power Distribution Box)

 

 

 

 

Output AC Parameters

 

 

Factory Default VAC

230VAC

 

 

 

 

Output Connections

Hardwire Terminal Block Standard

 

(See 3.3 - Removable Power Distribution Box)

 

 

 

 

 

 

Frequency

50Hz or 60Hz, Nominal

 

 

 

 

Waveform

Sinewave

 

 

 

 

Main Mode Overload

>200% for 5 cycles; 151 - 200% for 1 seconds; 131-150% 10

 

 

seconds; 105 - 130% 1 minute

Battery Parameters

 

 

Type

Valve-regulated, non-spillable, lead acid

 

Quantity x V

20 x 12V

 

 

 

 

Battery Mfr. / Part #

5AH battery, CSB HR1221W or YUASA NPH5-12

 

 

 

 

Backup Time

See Table 11 - Typical battery run times, minutes at 25°C

 

 

(77°F ), 100% resistive load and

 

Recharge Time (Internal Batteries)

3 hr. to 90% capacity after full discharge into 100% load

 

 

Bypass Protection Limits

 

 

Disable Bypass Operation

If input voltage exceeds ±15% of the nominal voltage

 

 

 

 

Re-Enable Bypass Operation

If input voltage returns to within ±10% of nominal output

 

voltage

 

 

 

Disable Bypass operation

When the input frequency prevents synchronous operation

 

 

Environmental

 

 

Operating Temperature, °C (°F)

0 to 40 (32 to 104) see Table 8 - Operating temperature

 

parameters

 

 

 

Storage Temperature, °C (°F)

-15 to 50 (5 to 122)

 

 

 

 

Relative Humidity

0-95% non-condensing

 

Operating Elevation

Up to 1000m (3281 ft) at 25°C (77°F) without derating

 

 

 

 

Audible Noise

<55 dBA at 1 meter from the rear;

 

<50 dBA, at 1 meter from the front or sides

 

 

34

Page 40
Image 40
Emerson GXT3 230V user manual Specifications, UPS specifications