Seagate ST9408114AB, ST9808211AB manual Acoustics, Electromagnetic immunity, Drive level acoustics

Page 18

2.11Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea- surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

Table 3:

Drive level acoustics

 

 

 

 

Acoustic mode

 

 

 

 

 

 

Idle*

 

Quiet Seek

Performance Seek

 

 

 

 

2.4 bels (typ)

 

2.6 bels (typ)

2.9 bels (typ)

2.6 bels (max)

2.8 bels (max)

3.1 bels (max)

 

 

 

 

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.

2.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the rradio frequency (RF) environments defined in the following table:

Table 4:

Electromagnetic immunity

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

 

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

ENV 50204: 95

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz

A

EN 61000-4-6: 97

 

 

sine

 

 

 

 

 

 

Power Frequency H-field

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

immunity

 

 

 

 

 

 

 

 

Voltage dips, interrupts

30% Reduction for 25 cycles

C

EN 61000-4-11: 94

 

 

>95% Reduction for 250 cycles

C

 

 

 

>95%, 0.5 cycles

B

 

 

 

 

 

 

A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.

2) No data loss.

B - 1) Unit self recovers without user intervention.

2) No data loss.

C - 1) Upset OK provided that unit will function after user intervention.

12

Momentus 5400.2 Blade Server Product Manual, Rev. B

Image 18 Contents
Momentus5400.2 Blade Server ST9100823AB ST9808211AB ST960822AB ST9408114ABPage Contents Momentus 5400.2 Blade Server Product Manual, Rev. B List of Figures Momentus 5400.2 Blade Server Product Manual, Rev. B Introduction Momentus 5400.2 Blade Server Pata disc driveMomentus 5400.2 Blade Server Product Manual, Rev. B Drive specifications Specification summarySpecifications To 90% operating Formatted capacity Default logical geometryLBA mode Physical organizationPhysical characteristics Technology SpecificationRecording and interface technology Typical seek times msec Read Write Seek timeTime to ready Time to ready Typical Max Power specifications Typical current profile Conducted noiseVoltage tolerance Environmental specifications Nonoperating shock ShockOperating shock VibrationDrive level acoustics AcousticsElectromagnetic immunity Electromagnetic immunityReliability Safety certificationMeasurement type Specification Agency certificationKorean RRL Australian C-Tick N176FCC verification Environmental protection Corrosive environmentEuropean Union Restriction of Hazardous Substances RoHS Momentus 5400.2 Blade Server Product Manual, Rev. B Jumper settings Configuring and mounting the driveHandling and static discharge precautions Master/slave configurationDrive mounting Cable-select optionConnector Cable Signal Name Contact Conductor ATA interface signals and connector pinsConnector signals Cable Connector Conductor Contact Signal NameSupported ATA commands Supported commandsCommand name Command code in hex ATA-standard commands Command name Command code in hex ATA-standard power-management commandsATA-standard security commands Supported commands Identify Device command Word Description ValueXx07H Bit Word Set Features command Features register valuesPresales Support Seagate Technology support servicesInternet Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index NumericsPage TMR Momentus 5400.2 Blade Server Product Manual, Rev. B Page Seagate Technology LLC