Seagate ES.2 FC, ST31000640FC manual Start/stop time, Prefetch/multi-segmented cache control

Page 20

4.2.3

General performance characteristics

 

Sustainable disc transfer rate*:

 

Minimum

56 Mbytes/sec

Maximum

116 Mbytes/sec

Fibre Channel Interface maximum instantaneous transfer rate

400 Mbytes/sec* per port

 

 

(dual port = 800 Mbytes/sec*)

Logical block sizes

 

Default is 512-byte data blocks

 

Sector sizes variable to 512, 520, 524 and 528 bytes.

 

Read/write consecutive sectors on a track

Yes

Flaw reallocation performance impact (for flaws reallocated at format time

Negligible

using the spare sectors per sparing zone reallocation scheme.)

 

*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.

4.3Start/stop time

The drive accepts the commands listed in the Fibre Channel Interface Manual less than 3 seconds after DC power has been applied.

If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).

If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.

The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 30 sec- onds (maximum) from removal of DC power.

There is no power control switch on the drive.

4.4Prefetch/multi-segmented cache control

The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual opera- tion, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2.

12

Barracuda ES.2 FC Product Manual, Rev. B

Image 20
Contents Barracuda ES.2 FC ST31000640FCPage Barracuda ES.2 FC Product Manual, Rev. B Barracuda ES.2 FC Product Manual, Rev. B Contents Physical/electrical specifications Defect and error managementInstallation Interface requirementsSeagate Technology support services Barracuda ES.2 FC Product Manual, Rev. B Scope Barracuda ES.2 FC Product Manual, Rev. B Standards, compliance and reference documents StandardsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Barracuda ES.2 FC Product Manual, Rev. B General description Standard features Media descriptionPerformance ReliabilityFormatted capacities Programmable drive capacityFactory-installed options User-installed accessoriesPerformance characteristics Internal drive characteristicsAccess time Format command execution time minutesPrefetch/multi-segmented cache control General performance characteristicsStart/stop time Cache operation Caching write dataPrefetch operation Reliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact MillisecondsReporting control Determining ratePredictive failures Thermal monitorState of the drive prior to testing Parameter Code DescriptionDrive Self Test DST DST failure definitionInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortShipping Product repair and return informationBarracuda ES.2 FC Product Manual, Rev. B Physical/electrical specifications AC power requirementsDC power requirements DC power requirements Gbit AmpsConducted noise immunity General DC power requirement notesPower sequencing Current profiles Power dissipation Relative humidity TemperatureEnvironmental limits Package size Packaged/product weight Drop height Effective altitude sea levelShock and vibration ShockAir cleanliness VibrationAcoustics Corrosive environmentX表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。 China Restriction of Hazardous Substances RoHS DirectiveMechanical specifications Mounting configuration dimensionsBarracuda ES.2 FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 51.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Deferred Auto-Reallocation Idle Read After WriteInstallation Drive ID/option selectionDrive orientation CoolingDrive mounting Air flowGrounding Barracuda ES.2 FC Product Manual, Rev. B FC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Barracuda ES.2 FC Product Manual, Rev. B Temperature page 0Dh Barracuda ES.2 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Block Descriptor Mode Sense Pages Data Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Power Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Barracuda ES.2 FC Product Manual, Rev. B Seagate Technology support services InternetPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index NumericsFAN Flogi Plogi SEL ID See also cooling

ST31000640FC, ES.2 FC specifications

The Seagate ES.2 FC, model ST31000640FC, is a high-performance hard drive designed specifically for enterprise environments. This drive is engineered to provide reliable and efficient data storage, catering to the demands of critical business applications, data centers, and server infrastructures.

One of the standout features of the ST31000640FC is its large storage capacity. With a 1TB capacity, it offers ample space for storing vast amounts of data, making it an excellent choice for businesses that require extensive storage solutions. This capacity enables the drive to support extensive databases, applications, and virtualized environments without compromising performance.

The Seagate ES.2 FC utilizes Fibre Channel (FC) interface technology, which is known for its high-speed data transfer capabilities. Operating at 4 Gbps, this interface facilitates faster communication between the drive and the server, significantly enhancing overall system performance. The Fibre Channel technology also improves data integrity through its ability to manage large amounts of data traffic efficiently.

In terms of performance specifications, the ST31000640FC boasts a rotational speed of 7200 RPM and a sustained data transfer rate that offers quick access to information. Additionally, it features an advanced caching mechanism that optimizes read and write operations, ensuring rapid data retrieval and improved application responsiveness.

The drive's advanced error recovery and data protection mechanisms, such as the Seagate PowerTrim technology, work to minimize downtime and data loss. This is particularly crucial for enterprise applications that demand high availability and reliability. PowerTrim intelligently manages the drive’s internal resources to enhance performance and durability.

Another essential characteristic of the Seagate ES.2 FC is its enterprise-grade reliability. It boasts a mean time between failures (MTBF) rating of 1.2 million hours, indicating its robustness for continuous operation in demanding environments. Furthermore, it is designed to operate in a range of temperatures, ensuring consistent performance across various operational conditions.

Lastly, the Seagate ES.2 FC incorporates vibration tolerance and advanced acoustic performance features, which help to reduce noise and ensure quieter operation in data center environments. This makes it an attractive option for enterprises looking to optimize their infrastructure while minimizing disturbances.

In summary, the Seagate ES.2 FC, ST31000640FC hard drive is an excellent choice for enterprises seeking a balance of large storage capacity, high-speed performance, and reliability in a Fibre Channel environment. With its array of technologies and robust characteristics, it meets the rigorous demands of modern business storage needs.