Seagate ST31000640FC, ES.2 FC Installation, Drive ID/option selection, Drive orientation, Cooling

Page 45

8.0Installation

Barracuda ES.2 FC disc drive installation is a plug-and-play process. There are no jumpers, switches, or termi- nators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC- SCA)no cables are required. See Section 9.5 for additional information about this connector.

Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.

If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL IDs) on the backpanel so that no two devices have the same selection ID. This is called the hard assigned arbi- trated loop physical address (AL_PA). There are 125 AL_PAs available (see Table 22). If you set the AL_PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec- tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto- matically.

Loop initialization is the process used to verify or obtain an address. The loop initialization process is per- formed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.

Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.

It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the drive only if you want to select a different logical block size.

8.1Drive ID/option selection

All drive options are made through the interface connector (J1). Table 19 provides the pin descriptions for the 40-pin Fibre Channel single connector (J1).

8.2Drive orientation

The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two pre- ferred mounting orientations.

8.3Cooling

The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 6.4.1.

Barracuda ES.2 FC Product Manual, Rev. B

37

Image 45
Contents ST31000640FC Barracuda ES.2 FCPage Barracuda ES.2 FC Product Manual, Rev. B Barracuda ES.2 FC Product Manual, Rev. B Contents Defect and error management Physical/electrical specificationsInstallation Interface requirementsSeagate Technology support services Barracuda ES.2 FC Product Manual, Rev. B Scope Barracuda ES.2 FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsBarracuda ES.2 FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Format command execution time minutesGeneral performance characteristics Start/stop timePrefetch/multi-segmented cache control Caching write data Cache operationPrefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorParameter Code Description State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationBarracuda ES.2 FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements Gbit AmpsGeneral DC power requirement notes Power sequencingConducted noise immunity Current profiles Power dissipation Temperature Environmental limitsRelative humidity Effective altitude sea level Package size Packaged/product weight Drop heightShock and vibration ShockVibration Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsBarracuda ES.2 FC Product Manual, Rev. B Defect and error management Drive internal defects/errorsDrive error recovery procedures 51.87 FC-AL system errors Background Media ScanMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Barracuda ES.2 FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Barracuda ES.2 FC Product Manual, Rev. B Temperature page 0Dh Mode Sense data Inquiry dataBarracuda ES.2 FC inquiry data Bytes Data hex Page Block Descriptor Mode Sense Pages Data Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Barracuda ES.2 FC Product Manual, Rev. B Internet Seagate Technology support servicesPresales Support Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi SEL ID See also cooling

ST31000640FC, ES.2 FC specifications

The Seagate ES.2 FC, model ST31000640FC, is a high-performance hard drive designed specifically for enterprise environments. This drive is engineered to provide reliable and efficient data storage, catering to the demands of critical business applications, data centers, and server infrastructures.

One of the standout features of the ST31000640FC is its large storage capacity. With a 1TB capacity, it offers ample space for storing vast amounts of data, making it an excellent choice for businesses that require extensive storage solutions. This capacity enables the drive to support extensive databases, applications, and virtualized environments without compromising performance.

The Seagate ES.2 FC utilizes Fibre Channel (FC) interface technology, which is known for its high-speed data transfer capabilities. Operating at 4 Gbps, this interface facilitates faster communication between the drive and the server, significantly enhancing overall system performance. The Fibre Channel technology also improves data integrity through its ability to manage large amounts of data traffic efficiently.

In terms of performance specifications, the ST31000640FC boasts a rotational speed of 7200 RPM and a sustained data transfer rate that offers quick access to information. Additionally, it features an advanced caching mechanism that optimizes read and write operations, ensuring rapid data retrieval and improved application responsiveness.

The drive's advanced error recovery and data protection mechanisms, such as the Seagate PowerTrim technology, work to minimize downtime and data loss. This is particularly crucial for enterprise applications that demand high availability and reliability. PowerTrim intelligently manages the drive’s internal resources to enhance performance and durability.

Another essential characteristic of the Seagate ES.2 FC is its enterprise-grade reliability. It boasts a mean time between failures (MTBF) rating of 1.2 million hours, indicating its robustness for continuous operation in demanding environments. Furthermore, it is designed to operate in a range of temperatures, ensuring consistent performance across various operational conditions.

Lastly, the Seagate ES.2 FC incorporates vibration tolerance and advanced acoustic performance features, which help to reduce noise and ensure quieter operation in data center environments. This makes it an attractive option for enterprises looking to optimize their infrastructure while minimizing disturbances.

In summary, the Seagate ES.2 FC, ST31000640FC hard drive is an excellent choice for enterprises seeking a balance of large storage capacity, high-speed performance, and reliability in a Fibre Channel environment. With its array of technologies and robust characteristics, it meets the rigorous demands of modern business storage needs.