Seagate ST3300656FC, ST3146356FC FC-AL transmitters and receivers, Pin Signal name Signal type

Page 76

Table 24: FC-SCA pin descriptions

Pin

Signal name

Signal type

 

 

 

1*

-EN bypass port A

Low Voltage TTL output

 

 

 

2*

12 Volts

 

 

 

 

3*

12 Volts

 

 

 

 

4*

12 Volts

 

 

 

 

5*

-Parallel ESI

 

 

 

 

6*

Ground[1]

 

7*

Active LED out

Open collector out

 

 

 

8*

Reserved

 

 

 

 

9*

Start_1[2]

TTL input

10*

Start_2[2]

TTL input

11*

-EN bypass port B

Low Voltage TTL output

 

 

 

12*

SEL_6

TTL input/output

 

 

 

13*

SEL_5

TTL input/output

 

 

 

14*

SEL_4

TTL input

 

 

 

15*

SEL_3

TTL input/output

 

 

 

16*

Fault LED out

Open collector out

 

 

 

17*

DEV_CTRL_CODE_2[2]

TTL input

18*

DEV_CTRL_CODE_1[2]

TTL input

19*

5 Volts

 

 

 

 

20*

5 Volts

 

 

 

 

Pin

Signal name

Signal type

 

 

 

21

12 Volts charge

 

 

 

 

22

Ground

 

 

 

 

23

Ground

 

 

 

 

24*

+Port A_in

FC Diff. input pair

 

 

 

25*

-Port A_in

 

 

 

 

26

Ground

 

 

 

 

27*

+Port B_in

FC Diff. input pair

 

 

 

28*

-Port B_in

 

 

 

 

29

Ground

 

 

 

 

30*

+Port A_out

FC Diff. output pair

 

 

 

31*

-Port A_out

 

 

 

 

32

Ground

 

 

 

 

33*

+Port B_out

FC Diff. output pair

 

 

 

34*

-Port B_out

 

 

 

 

35

Ground

 

 

 

 

36

SEL_2

TTL input/output

 

 

 

37

SEL_1

TTL input/output

 

 

 

38

SEL_0

TTL input/output

 

 

 

39

DEV_CTRL_CODE_0[2

TTL input

40

5 Volts charge

 

 

 

 

*Short pins in mating backpanel connector.

[1]This pin may be connected to external logic to detect the presence of the drive. The drive connects this pin to the common ground.

[2]Pins 9, 10, 17, 18, and 39 are option select pins and are tied high by the drive circuitry. The preferred elec- trical connection at the backplane is either open or grounded (open for the ‘1’ setting, grounded for the ‘0’ setting). Alternatively, these pins may be driven by a 3.3V logic device, pulled up to 3.3V through a pull-up resistor (recommended size of 10k ohm), or grounded through some other means.

9.5.5FC-AL transmitters and receivers

A typical FC-AL differential copper transmitter and receiver pair is shown in Figure 14. The receiver is required to provide the AC coupling to eliminate ground shift noise.

TX

Transmitter 100

TY

.01

Differential

Transfer Medium

.01

RX

Receiver 100

RY

Figure 14. FC-AL transmitters and receivers

68

Cheetah 15K.6 FC Product Manual, Rev. A

Image 76 Contents
Cheetah 15K.6 FC ST3450856FC ST3300656FC ST3146356FCPage Contents Installation Defect and error managementInterface requirements Seagate Technology support services Cheetah 15K.6 FC Product Manual, Rev. a List of Figures Page Scope Cheetah 15K.6 FC Product Manual, Rev. a Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-20Cheetah 15K.6 FC Product Manual, Rev. a General description Standard features Media descriptionFactory-installed options PerformanceReliability Formatted capacitiesUser-installed accessories Performance characteristics Internal drive characteristicsSeek performance characteristics Access timeFormat command execution time minutes General performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write dataPrefetch operation Reliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact MillisecondsReporting control Determining ratePredictive failures Thermal monitorState of the drive prior to testing Parameter Code DescriptionDrive Self Test DST DST failure definitionInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortShipping Product repair and return informationCheetah 15K.6 FC Product Manual, Rev. a Physical/electrical specifications AC power requirementsDC power requirements DC power requirements for ST3450856FC model Gbit AmpsDC power requirements for ST3300656FC model Gbit Amps DC power requirements for ST3146356FC model Gbit AmpsGeneral DC power requirement notes Power sequencingConducted noise immunity Current profilesTypical ST3450856FC current profiles Typical ST3300656FC current profiles Typical ST3146356FC current profiles Power dissipation ST3450856FCST3300656FC Environmental limits TemperatureST3146356FC Relative humidity Effective altitude sea levelShock and vibration ShockPackage size Packaged/product weight Drop height Recommended mounting Air cleanliness VibrationAcoustics Corrosive environmentRoHS compliance statement Mechanical specifications Mounting configuration dimensionsCheetah 15K.6 FC Product Manual, Rev. a Drive internal defects/errors Defect and error managementDrive error recovery procedures Page FC-AL system errors Background Media ScanMedia Pre-Scan Deferred Auto-ReallocationIdle Read After Write Cheetah 15K.6 FC Product Manual, Rev. a Installation Drive ID/option selectionDrive orientation CoolingDrive mounting Air flowGrounding Cheetah 15K.6 FC Product Manual, Rev. a FC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah 15K.6 FC Product Manual, Rev. a Temperature page 0Dh Inquiry data Mode Sense dataCheetah 15K.6 FC inquiry data Bytes Data hex Page Mode Data Header 000000 Cheetah 15K.6 FC Product Manual, Rev. a Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions Pin Signal name Signal type FC-SCA pin descriptions Pin Signal name Signal typeFC-AL transmitters and receivers Power Fault LED OutActive LED Out Enable port bypass signalsMotor start controls Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesArbitrated loop physical address Alpa values SettingHex Dec TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah 15K.6 FC Product Manual, Rev. a Seagate Technology support services InternetPresales Support Technical SupportData Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index NumericsFAN Flogi Plogi Page See also cooling