Seagate ST3450857FC, ST3300557FC manual Reliability and service, Seek errors, Interface errors

Page 21

6.1.3Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

6.1.4Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error. The total error rate for a loop of devices is the sum of the individual device error rates.

6.2Reliability and service

You can enhance the reliability of Cheetah 15K.6 disc drives by ensuring that the drive receives adequate cool- ing. Section 7.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 11.2 provides recommended air-flow information.

6.2.1Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)

These drives shall achieve an AFR of 0.55% (MTBF of 1,600,000 hours) when operated in an environment that ensures the HDA case temperatures do not exceed the values specified in Section 7.4.1.

Operation at case temperatures outside the specifications in Section 7.4.1 may increase the AFR (decrease the MTBF). AFR and MTBF statistics are poplulation statistics that are not relevant to individual units.

AFR and MTBF specifications are based on the following assumptions for Enterprise Storage System environ- ments:

8,760 power-on hours per year

250 average on/off cycles per year

Operating at nominal voltages

System provides adequate cooling to ensure the case temperatures specified in Section 7.4.1 are not exceeded.

6.2.2Preventive maintenance

No routine scheduled preventive maintenance is required.

6.2.3Hot plugging the drive

Inserting and removing the drive on the FC-AL will interrupt loop operation. The interruption occurs when the receiver of the next device in the loop must synchronize to a different input signal. FC error detection mecha- nisms, character sync, running disparity, word sync, and CRC are able to detect any error. Recovery is initiated based on the type of error.

The disc drive defaults to the FC-AL Monitoring state, Pass-through state, when it is powered-on by switching the power or hot plugged. The control line to an optional port bypass circuit (external to the drive), defaults to the Enable Bypass state. If the bypass circuit is present, the next device in the loop will continue to receive the output of the previous device to the newly inserted device. If the bypass circuit is not present, loop operation is temporarily disrupted until the next device starts receiving the output from the newly inserted device and regains synchronization to the new input.

The Pass-through state is disabled while the drive performs self test of the FC interface. The control line for an external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is

Cheetah 15K.7 FC Product Manual, Rev. C

15

Image 21
Contents ST3600857FC ST3450657FC ST3300457FC Standard models Self-Encrypting Drive modelsSED Fips 140-2 models Page Contents Installation Defect and error managementAbout Fips About self-encrypting drives Interface requirementsCheetah 15K.7 FC Product Manual, Rev. C Iii Cheetah 15K.7 FC Product Manual, Rev. C Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsGeneral description Standard features Performance Media descriptionReliability Formatted capacitiesFactory-installed options User-installed accessoriesProgrammable drive capacity Internal drive characteristics Performance characteristicsSeek performance characteristics Access timeGeneral performance characteristics Format command execution time minutesStart/stop time ST3600057FC ST3450857FC ST3300657FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Temperature Log Page 0DhPredictive failures Thermal monitorDrive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entriesProduct warranty ShippingProduct repair and return information Physical/electrical specifications AC power requirementsDC power requirements ST3450857FC DC power requirements Gbit Amps ST3600057FC DC power requirements Gbit AmpsST3300657FC DC power requirements Gbit Amps General DC power requirement notesPower sequencing Conducted noise immunityCurrent profiles Typical ST3450857FC current profiles Typical ST3300657FC current profiles 600GB model Power dissipation450GB models Temperature a. Operating Environmental limits300GB models Effective altitude sea level a. Operating Relative humidityPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environment RoHS compliance statementElectromagnetic susceptibility See Section Mounting configuration dimensions Mechanical specificationsAbout Fips PurposeLevel 2 security Admin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseDefect and error management Drive internal defects/errorsDrive error recovery procedures Page These values are subject to change FC-AL system errorsBackground Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Installation Drive ID/option selectionDrive orientation Air flow CoolingGrounding Drive mountingFibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel port login accept NPort Login Accept ACC payload BytesProcess Login Plri payload Fibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginDual port support Scsi commands supportedFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. C Cheetah 15K.7 FC Product Manual, Rev. C Background Medium Scan 15h Mode Sense data Inquiry dataCheetah 15K.7 FC inquiry data Bytes Data hex Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 12.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristics provides the TTL characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Numerics IndexDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. C
Related manuals
Manual 90 pages 18.12 Kb