Seagate ST3300657FC, ST3300557FC, ST3300457FC, ST3450857FC manual General DC power requirement notes

Page 29

Table 4:

ST3300657FC DC power requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Gbit

 

4 Gbit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

(Amps)

(Amps)

(Amps)

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

+5V

+12V [2]

+5V

+12V [2]

 

 

 

 

 

 

 

 

 

 

 

 

Regulation

 

 

 

 

 

 

[5]

±5%

±5% [2]

±5%

±5% [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] [7]

0.39

0.59

0.39

0.59

Avg idle current DCX

 

 

 

 

 

 

 

 

 

Maximum starting current

 

 

 

 

 

 

(peak DC) DC

3σ

[3]

0.62

1.91

0.62

1.91

(peak AC) AC

3σ

[3]

0.96

3.75

0.98

3.57

 

 

 

 

 

 

 

Delayed motor start (max) DC

3σ

[1] [4]

0.56

0.04

0.56

0.04

 

 

 

 

 

 

 

Peak operating current:

 

 

 

 

 

 

 

 

 

 

[1] [6]

0.48

0.92

0.48

0.91

Typical DCX

 

 

Maximum DC

3σ

[1]

0.53

1.00

0.53

0.95

Maximum (peak) DC

3σ

 

1.32

2.80

1.32

2.72

 

 

 

 

 

 

 

 

 

 

 

 

[1]Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val- ues. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.

[2]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 15000 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See +12V current profile in Figure 1.

[4]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.

[5]See paragraph 7.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.

[6]Operating condition is defined as random 8 block reads at 375 I/Os per second for 600GB models and 380 I/Os per second for 450GB and 300GB models. Current and power specified at nominal voltages.

[7]During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track.

General DC power requirement notes.

1.Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current shown.

2.The +5V and +12V supplies should employ separate ground returns.

3.Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.

4.Parameters, other than spindle start, are measured after a 10-minute warm up.

5.No terminator power.

Cheetah 15K.7 FC Product Manual, Rev. C

23

Image 29
Contents SED Fips 140-2 models ST3600857FC ST3450657FC ST3300457FCStandard models Self-Encrypting Drive models Page Contents Installation Defect and error managementAbout Fips About self-encrypting drives Interface requirementsCheetah 15K.7 FC Product Manual, Rev. C Iii Cheetah 15K.7 FC Product Manual, Rev. C Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsGeneral description Standard features Performance Media descriptionReliability Formatted capacitiesProgrammable drive capacity Factory-installed optionsUser-installed accessories Internal drive characteristics Performance characteristicsSeek performance characteristics Access timeGeneral performance characteristics Format command execution time minutesStart/stop time ST3600057FC ST3450857FC ST3300657FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Temperature Log Page 0DhPredictive failures Thermal monitorDrive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entries Product repair and return information Product warranty Shipping DC power requirements Physical/electrical specificationsAC power requirements ST3450857FC DC power requirements Gbit Amps ST3600057FC DC power requirements Gbit AmpsST3300657FC DC power requirements Gbit Amps General DC power requirement notesCurrent profiles Power sequencingConducted noise immunity Typical ST3450857FC current profiles Typical ST3300657FC current profiles 600GB model Power dissipation450GB models 300GB models Temperature a. OperatingEnvironmental limits Effective altitude sea level a. Operating Relative humidityShock Package size Packaged/product weight Drop heightShock and vibration Recommended mounting Acoustics Air cleanlinessVibration a. Operating-normal Electromagnetic susceptibility See Section Corrosive environmentRoHS compliance statement Mounting configuration dimensions Mechanical specificationsLevel 2 security About FipsPurpose Admin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseDrive error recovery procedures Defect and error managementDrive internal defects/errors Page These values are subject to change FC-AL system errorsDeferred Auto-Reallocation Background Media ScanMedia Pre-Scan Idle Read After Write Drive orientation InstallationDrive ID/option selection Air flow CoolingGrounding Drive mountingFibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Fibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginDual port support Scsi commands supportedFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. C Cheetah 15K.7 FC Product Manual, Rev. C Background Medium Scan 15h Cheetah 15K.7 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 12.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics provides the TTL characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Numerics IndexDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. C
Related manuals
Manual 90 pages 18.12 Kb