Seagate ST3450857FC, ST3300557FC manual FC-AL system errors, These values are subject to change

Page 48

Table 5: Read and write retry count maximum recovery times [1]

Read retry

Maximum recovery time per LBA

count

(cumulative, msec)

 

 

0

51.87

 

 

1

59.85

 

 

2

203.49

 

 

3

231.42

 

 

4

295.26

 

 

5

327.18

 

 

6

359.10

 

 

7

446.88

 

 

8

538.65

 

 

9

570.57

 

 

10

598.50

 

 

11 (default)

1,534.97

 

 

[1]These values are subject to change.

Write retry

Maximum recovery time per LBA

count

(cumulative, msec)

 

 

0

23.94

 

 

1

35.91

 

 

2

39.9

 

 

3

51.87

 

 

4

79.8

 

 

5 (default)

107.73

 

 

Setting these retry counts to a value below the default setting could result in an increased unrecovered error rate which may exceed the value given in this product manual. A setting of zero (0) will result in the drive not performing error recovery.

For example, suppose the Read/Write Recovery page has the RC bit set to 0, read retry count set to 4, and the recovery time limit field (Mode Sense page 01, bytes 10 and 11) set to FF FF hex (maximum). A four LBA Read command is allowed to take up to 253.11 msec recovery time for each of the four LBAs in the command. If the recovery time limit is set to 00 C8 hex (200 msec decimal) a four LBA read command is allowed to take up to 200 msec for all error recovery within that command. The use of the Recovery Time Limit field allows finer granularity on control of the time spent in error recovery. The recovery time limit only starts counting when the drive is executing error recovery and it restarts on each command. Therefore, each command’s total recovery time is subject to the recovery time limit. Note: A recovery time limit of 0 will use the drive’s default value of FF FF. Minimum recovery time limit is achieved by setting the Recovery Time Limit field to 00 01.

10.3FC-AL system errors

Information on the reporting of operational errors or faults across the interface is given in the Fibre Channel Interface Manual. The FCP Response returns information to the host about numerous kinds of errors or faults. The Receive Diagnostic Results reports the results of diagnostic operations performed by the drive.

Status returned by the drive to the initiator is described in the Fibre Channel Interface Manual. Status reporting plays a role in systems error management and its use in that respect is described in sections where the various commands are discussed.

42

Cheetah 15K.7 FC Product Manual, Rev. C

Image 48
Contents ST3600857FC ST3450657FC ST3300457FC Standard models Self-Encrypting Drive modelsSED Fips 140-2 models Page Contents Defect and error management InstallationAbout Fips About self-encrypting drives Interface requirementsCheetah 15K.7 FC Product Manual, Rev. C Iii Cheetah 15K.7 FC Product Manual, Rev. C Seagate Technology support services Seagate Online Support and ServicesScope Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-20General description Standard features Media description PerformanceReliability Formatted capacitiesFactory-installed options User-installed accessoriesProgrammable drive capacity Performance characteristics Internal drive characteristicsSeek performance characteristics Access timeFormat command execution time minutes General performance characteristicsStart/stop time ST3600057FC ST3450857FC ST3300657FCPrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact MillisecondsTemperature Log Page 0Dh Determining ratePredictive failures Thermal monitorState of the drive prior to testing Drive Self Test DSTDST failure definition ImplementationShort and extended tests Short test Function Code 001bExtended test Function Code 010b Log page entriesProduct warranty ShippingProduct repair and return information Physical/electrical specifications AC power requirementsDC power requirements ST3600057FC DC power requirements Gbit Amps ST3450857FC DC power requirements Gbit AmpsGeneral DC power requirement notes ST3300657FC DC power requirements Gbit AmpsPower sequencing Conducted noise immunityCurrent profiles Typical ST3450857FC current profiles Typical ST3300657FC current profiles Power dissipation 600GB model450GB models Temperature a. Operating Environmental limits300GB models Relative humidity Effective altitude sea level a. OperatingPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environment RoHS compliance statementElectromagnetic susceptibility See Section Mechanical specifications Mounting configuration dimensionsAbout Fips PurposeLevel 2 security Controlled access Admin SPAbout self-encrypting drives Data encryptionDefault password Random number generator RNGDrive locking Data bandsAuthenticated firmware download Power requirementsSupported commands Cryptographic eraseDefect and error management Drive internal defects/errorsDrive error recovery procedures Page FC-AL system errors These values are subject to changeBackground Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Installation Drive ID/option selectionDrive orientation Cooling Air flowDrive mounting GroundingFC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept NPort Login Accept ACC payload BytesProcess Login Plri payload Fibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesScsi commands supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. C Cheetah 15K.7 FC Product Manual, Rev. C Background Medium Scan 15h Mode Sense data Inquiry dataCheetah 15K.7 FC inquiry data Bytes Data hex Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Power Fault LED OutEnable port bypass signals Active LED OutMotor start controls Parallel Enclosure Services Interface ESI 12.5.11 SEL6 through SEL0 ID linesSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristics provides the TTL characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Index NumericsDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. C
Related manuals
Manual 90 pages 18.12 Kb