3.0Applicable standards and reference documentation

The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achieve opti- mum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regu- lation. In particular, the drive must be securely mounted in order to guarantee the specified performance char- acteristics. Mounting by bottom holes must meet the requirements of Section 11.4.

3.1Standards

The Cheetah 15K.7 FC family complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate Fibre Channel Interface Manual, part number 100293070.

The drives are recognized in accordance with UL 60950-1 and CSA 60950-1 as tested by UL and EN60950-1 as tested by TUV.

The security features of Cheetah 15K.7 FC SED models are based on the “TCG Storage Architecture Core Specification” and the “TCG Storage Workgroup Security Subsystem Classs: Enterprise_A” specification with additional vendor-unique features as noted in this product manual.

3.1.1Electromagnetic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. As such the drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communica- tions.

The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. As such, the drive is capable of meeting the Class B limits of the FCC Rules and Regula- tions of the Canadian Department of Communications when properly packaged. However, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host con- troller.

3.1.1.1Electromagnetic susceptibility

As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Table 2, DC power requirements.

Cheetah 15K.7 FC Product Manual, Rev. C

3

Image 9
Contents ST3600857FC ST3450657FC ST3300457FC Standard models Self-Encrypting Drive modelsSED Fips 140-2 models Page Contents Installation Defect and error managementAbout Fips About self-encrypting drives Interface requirementsCheetah 15K.7 FC Product Manual, Rev. C Iii Cheetah 15K.7 FC Product Manual, Rev. C Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsGeneral description Standard features Performance Media descriptionReliability Formatted capacitiesFactory-installed options User-installed accessoriesProgrammable drive capacity Internal drive characteristics Performance characteristicsSeek performance characteristics Access timeGeneral performance characteristics Format command execution time minutesStart/stop time ST3600057FC ST3450857FC ST3300657FCCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Temperature Log Page 0DhPredictive failures Thermal monitorDrive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entriesProduct warranty ShippingProduct repair and return information Physical/electrical specifications AC power requirementsDC power requirements ST3450857FC DC power requirements Gbit Amps ST3600057FC DC power requirements Gbit AmpsST3300657FC DC power requirements Gbit Amps General DC power requirement notesPower sequencing Conducted noise immunityCurrent profiles Typical ST3450857FC current profiles Typical ST3300657FC current profiles 600GB model Power dissipation450GB models Temperature a. Operating Environmental limits300GB models Effective altitude sea level a. Operating Relative humidityPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environment RoHS compliance statementElectromagnetic susceptibility See Section Mounting configuration dimensions Mechanical specificationsAbout Fips PurposeLevel 2 security Admin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseDefect and error management Drive internal defects/errorsDrive error recovery procedures Page These values are subject to change FC-AL system errorsBackground Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Installation Drive ID/option selectionDrive orientation Air flow CoolingGrounding Drive mountingFibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel port login accept NPort Login Accept ACC payload BytesProcess Login Plri payload Fibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginDual port support Scsi commands supportedFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. C Cheetah 15K.7 FC Product Manual, Rev. C Background Medium Scan 15h Mode Sense data Inquiry dataCheetah 15K.7 FC inquiry data Bytes Data hex Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 12.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristics provides the TTL characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Numerics IndexDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. C