Teledyne 2102 installation and operation guide Testing Installation

Page 23

2102 Wireless Communication Module

Section 3 Preparation and Installation

3.3.2 Testing Installation

Note

The remote wireless module must be connected to a 2100 Series measurement module below it (or other compatible equipment) to function properly. By itself, it cannot measure anything; it is merely a radio frequency transmitter of data gen- erated by the connected measurement module.

When first powered up or after completing a connection, the remote will attempt to connect for 30 seconds. This is a good way to ensure that the unit is operating correctly. If the light does not blink for 30 seconds shortly after applying power, the unit is not operating properly.

CAUTION

User should not attempt to operate two base units within the same area. Crosstalk will result and prevent proper operation. This is not the case for the remotes, however. As many remotes as are necessary for the application may be installed.

The remote module program is updated when one of the fol- lowing conditions occurs:

Power is recycled.

After a successful connection with a base unit.

After a direct connection.

3-5

Image 23
Contents Wireless Communication Module Page Foreword Page Table of Contents Wireless Communication ModuleList of Tables List of FiguresGetting Started Quick Start GuideItem No Description Wireless ModuleWireless Module Components Top View Components2102 Components Bottom View Wireless Module Components Bottom ViewUpper Connector Capped System Connections Remote unit cable configurations Base unit cable configurationsOverview Wireless ModuleIntroduction Wireless Module Features Applications Controls, Connectors, and IndicatorsTop/Right View Bottom/Left View Item No Name Description Technical SpecificationsControls, Connectors, and Indicators 2102 Module Technical Specifications 2102 ModuleTechnical Specifications 2191 Battery Module Technical Specifications Spread Spectrum RadioPin Name Description Wireless Module Connector PinsUnpacking Instructions Preparation and InstallationPreparing for Installation Wireless Communication Module Preparation and Installation InstallationWireless Communication Module Preparation and Installation Wireless Communication Module Preparation and Installation Testing Installation Wireless Communication Module Preparation and Installation Section Overview ProgrammingRemote Unit Configuration Base Unit ConfigurationBase Module Connect Cables Cable or Power Option Part Number Description Refer to FigWireless Communication Module Programming Cleaning MaintenanceMaintenance Overview How to Obtain ServiceWireless Communication Module Maintenance Teledyne Isco, Inc Appendix a Replacement PartsReplacement Parts Diagrams and Listings Wireless Communication Module Appendix a Replacement Parts Fig. A-1 Item No Part Number DescriptionWireless Communication Module Appendix a Replacement Parts Table Hazmat 2100 Nodes 60-2003-550 Rev Page Teledyne Isco One Year