VXI SM8000 user manual Command SET, Command Transmit Data Receive Data Byte Byte Count

Page 61

VXI Technology, Inc.

COMMAND SET

Table 4-2lists the command set available for the SM8101 / SM8102 Optical Attenuator. The table lists the commands in alphabetical order. Detailed descriptions, listed in numeric order, follow the table.

TABLE 4-2: ATTENUATOR COMMAND SET

 

Command

 

 

Command

 

Transmit Data

 

Receive Data

 

 

 

 

Byte

 

Byte Count

 

Byte Count

 

 

 

 

 

 

 

 

 

Move To Absolute Step

 

30h

2

 

N/A

 

 

 

 

 

 

 

 

Power Down Motor

 

35h

N/A

 

N/A

 

Power Down Motor

 

43h

N/A

 

N/A

 

 

 

 

 

 

 

 

Power Down Motor

 

6Ch

N/A

 

N/A

 

 

 

 

 

 

 

 

Query Attenuation

 

81h

N/A

2

 

 

Query Calibration Date

 

8Bh

N/A

3

 

 

 

 

 

 

 

 

 

Query Calibration Table Entry

 

8Eh

2

2

 

 

 

 

 

 

 

 

 

Query Calibration Temperature

 

8Ah

N/A

1

 

 

Query Calibration Wavelength

 

89h

N/A

2

 

 

 

 

 

 

 

 

 

Query Current Step

 

31h

N/A

2

 

 

 

 

 

 

 

 

 

Query Device ID

 

8Dh

N/A

3

 

 

Query Firmware Revision

 

8Ch

N/A

2

 

 

Query Maximum Attenuation

 

83h

N/A

2

 

 

 

 

 

 

 

 

 

Query Minimum Attenuation

 

82h

N/A

2

 

 

Reset Device

 

32h

N/A

 

N/A

 

Reset Device

 

96h

N/A

 

N/A

 

 

 

 

 

 

 

 

Reset Device

 

A2h

N/A

 

N/A

 

 

 

 

 

 

 

 

Set Attenuation

 

80h

2

 

N/A

 

Set Address

 

90h

1

 

N/A

SM8000 Series Programming

61

Image 61
Contents SM8000 Series VXI Technology, Inc Table of Contents Control Modes VXI Technology, Inc SM8000 Series Preface Certification Steve Mauga, QA Manager EMCVXI Technology, Inc SM8000 Series Preface Terms and Symbols Service should only be performed by qualified personnelAvoid Electric Shock Support Resources VXI Technology, Inc SM8000 Series Preface Overview SectionSM8000 Series Optical Switch Controller Configurations SM8001 / SM8002 MULTI-CHANNELSWITCHESDuplex 1 x N PDL6 SM8001 / SM8002 Multi Switch SpecificationsSpdt SM8003 Prism SwitchesPDL3 SM8003 Prism Switch SpecificationsPDL SM8101 / SM8102 Optical AttenuatorsSetting the Chassis Backplane Jumpers Calculating System Power and Cooling RequirementsIntroduction Example Setting the Logical AddressMSB LSB Selecting the Extended Memory Space Mating Optical Connectors Cleaning Optical ConnectorsOptical Connections General Description SM8001 / SM8002 Multi-Channel SwitchesSM8003 Prism Switches SM8003 Prism SwitchesSM8101 / SM8102 Optical Attenuators Attenuator DiagramOperation Resetting the SwitchRelay Registers Output Channel Selection N Switch Configuration Common Active Channel Duplex 1 x N Switch ConfigurationN Blocking Switch Configuration N Non-Blocking Switch Configuration 8MULTI-SWITCH Timing Calculating Switching TimeSM8003 Prism Switches Control Modes Starting the DeviceUncalibrated Operation Move-To-Absolute-Step Calibrated OperationError Status Busy SignalResetting the Device Commanding the DevicesAddressing Register AccessOffset Write Function Smip II Register MAP A16Logical Address Register Write Only ID Register Read OnlyDevice Type Register Read Only Status Register Read OnlyOffset Register Read and Write Control Register Write OnlySerial Number High Register Read Only Serial Number Low Register Read OnlyInterrupt Control Register Read and Write Interrupt Status Register Read OnlySubclass Register Read Only NVM Access Register Write NVM Access Register ReadBoard X, Y Used Address Register Read and Write Trace RAM Start High Register Read and WriteTrace RAM End Low Register Read and Write Trace RAM End High Register Read and WriteTrace RAM Address High Register Read and Write Trace RAM Address LOW Register Read and WriteTTL Trigger Polarity Register Write Only Open Trigger Select Register Write OnlyBusy Trigger Control Register Read and Write Trace RAM Control Register Read and WriteBoard Busy Register Read Only Trigger Advance Register Write OnlyReserved Registers Read and Write 1MB RAM Control Register Read and Write See Typical Optical Multi Switch OperationControl Register Delay Register Read and Write Plug-In LA+0x104 Command Register Write Only Address Register Write Only Relay Register Offset Device MemoryWriting to the Relay Registers Relay Register 00 Read and WriteRegister 02 thru 08 Read and Write Relay Optical Module’s Data Attenuation LevelRegister 0A thru 0C Read Programming Examples Typical Optical MULTI-SWITCH Control ExampleWrite Typical Optical Attenuator Control ExampleVXI Technology, Inc Read Example Write ExampleCommand Transmit Data Receive Data Byte Byte Count Command SET31h 30h35h 32h80h 6Ch82h 81h89h 83h8Bh 8Ah8Dh 8Ch8Eh Recommends That the Optical MODULE’S 90hConvert to hexadecimal A2h 96hVXI Technology, Inc SM8000 Series Programming Index VXIbus

SM8000 specifications

The VXI SM8000 is a versatile and robust modular instrumentation platform that is designed for various testing applications in industries such as aerospace, telecommunications, and military. This advanced test equipment is part of the VXI (Versatile Instrumentation System) standards, which allow for high-speed data acquisition, processing, and analysis.

One of the main features of the VXI SM8000 is its modular architecture, which enables users to configure the system according to their specific testing needs. This flexibility means that users can integrate various modules, including signal generators, oscilloscopes, and digital multimeters, making the system adaptable to a wide range of applications. The modular design also ensures scalability, allowing for easy expansion as test requirements grow.

The VXI SM8000 supports high-speed communication via its advanced backplane design. This design features multiple data buses that facilitate fast communication between modules, ensuring minimal latency and enhanced performance during testing. Moreover, the system is built to accommodate high-density modules, maximizing the amount of test parameters that can be handled simultaneously.

The SM8000 boasts enhanced signal processing capabilities thanks to its digital signal processing (DSP) technology. This feature enables real-time analysis and processing of signals, which is crucial for applications that require rapid feedback and adjustments. Additionally, the system is equipped with high-resolution analog-to-digital converters, ensuring precise measurement and analysis.

One of the key characteristics of the VXI SM8000 is its reliability. Built with robust materials and advanced engineering, the system is designed to endure rigorous testing environments and extreme operating conditions. This durability ensures consistent performance over time, making it a reliable choice for critical applications.

Furthermore, the VXI SM8000 is compatible with various software platforms, enabling seamless integration into existing testing environments. It supports programming languages like LabVIEW and MATLAB, allowing engineers to develop customized test scripts and configurations easily.

In summary, the VXI SM8000 is a powerful and flexible test system that combines modularity, high-speed communication, advanced signal processing, and compatibility with industry-standard software. Its reliability and scalability make it an ideal choice for professionals seeking a comprehensive testing solution across various sectors.